3.1.2 Download
Test
3.1.2.1 Description
The
VL2C luminaire has the ability to use downloaded test software to aid
in troubleshooting. A software test program exists in Artisan® Plus,
mini-Artisan®2, and mini-Artisan® plus control consoles. After the
software has been downloaded from the control console to the luminaire,
the luminaire can perform tests to help determine a faulty assembly. Most
luminaire functions have the ability to generate error codes when tested and
display errors at console control board window. The tests may be
activated by setting the thumbwheel address to a corresponding test
position or controlled from the console.
3.1.2.2 Test
Number
The two least significant digits of the test are defined as the test number.
The most significant digit is defined as the parameter for the selected test.
Not all tests have selectable parameters, but on those that do, it will alter
an aspect of the test. For example, speed of oscillation during a movement
test.
Note: Thumbwheel switches are oriented so readout appears normal when
the luminaire is suspended from a truss with head downward. If the
luminaire is setting on a flat surface instead of hanging, thumbwheel
numbers will appear upside down and the least significant digit will be on
the left.
NUMBERS READ UPSIDE
INSTALLED IN CHASSIS AS
DOWN WHEN BOARD IS
SHOWN
THUMBWHEEL
TEST NUMBER
PARAMETER
0
0
0
MSD
LSD