Test X21 - Sensor Test
The sensor test reads the state of a selected sensor. The parameter setting
determines which sensor is selected for test. A flashing LED on the CIB
PCB indicates an open sensor. A lit LED indicates a closed (detected)
sensor. Select test and manually move function across sensor range
(engage microswitch for intensity or rotate black stripe on wheel in front of
sensor).
Parameter settings for test X21 are as follows:
Parameter Test setting
Test Results
521
Intensity sensor
621
Color wheel 1
721
Color wheel 2
821
Gobo wheel
Test X22 - Pan Encoder Test
This test reads shaft encoder position and displays position in hexidecimal
on the control console. This test must be run from a control console and
cannot be run from an independent luminaire powered by a cheater cable.
Pan position is read one hexidecimal position at a time. Test parameter
setting determines which digit is displayed on console. Enter test number
and manually adjust Pan rotation knob. Smooth, sequential increments
indicate proper data from encoder.
Parameter settings for test X22 are as follows:
Parameter Test setting
Test Results
922
Most Significant Digit of pan position
from encoder. MSD reads 1,2, or 3 only.
822
Middle digit of pan position. Readout is
from 0 through F.
(0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F)
722
Least Significant Digit of pan position
from encoder. LSD readout is 0 to F.
(0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F)