Step 5.
Prepare replacement sensor and replace sensor on bulkhead.
a. At replacement sensor, trim wires to 9 inches.
b. Using MTA100 hand crimper, crimp sensor wires to blue,
four-pin MTA100 connector using the following pinouts:
Pin
Wire
4
Green
3
White
2
Black
1
Red
c. Install replacement sensor and return gobo/beam projector
assembly to luminaire head by doing Steps 2 and 3 in
reverse. Install tie wraps.
Step 6.
Calibrate sensor. Refer to Color and Gobo Wheel Sensor
Calibration paragraph.