Test X01 - Pan Servo
When test X01 is executed, the pan motor drives the yoke against the pan
stop in each direction. The yoke continues to pan back-and-forth until the
test setting is changed. Failure is indicated if the yoke pans with jerky
movements, too slowly, not at all, or remains against the stop.
Parameter settings for test X01 are as follows:
Parameter Test setting
Test Results
001
4 second pan from stop to stop
101
same as above
201
same as above
301
6 second pan from stop to stop
401
8 second pan from stop to stop
501
10 second pan from stop to stop
601
16 second pan from stop to stop
701
45 second pan from stop to stop
801
pan to stop
901
pan to stop
Test X02 - Tilt Servo
When test X02 is executed, the tilt motor drives the head against the tilt
stop in each direction. The head continues to tilt back- and-forth until the
test setting is changed. Failure is indicated if the head tilts with jerky
movements, too slowly, not at all, or remains against the stop.
Parameter settings for test X02 are as follows:
Parameter Test setting
Test Results
002
4 second tilt from stop to stop
102
same as above
202
same as above
302
6 second tilt from stop to stop
402
8 second tilt from stop to stop
502
10 second tilt from stop to stop
602
16 second tilt from stop to stop
702
45 second tilt from stop to stop
802
tilt to stop
902
tilt to stop