Rev: 06.28.18
Page 14
CCD-0001519
OneControl Touch Panel or OneControl App Error Codes
Touch Panel
Message
What's Happening?
What Should I Do?
"EXCESS ANGLE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
"EXCESSIVE ANGLE"
Excessive angle reached during
manual operation.
Stop manual operation and reset jacks to
a more level state. The code will self clear.
There is no need to hit "OK."
"BAD CALIBRATION"
Trailer zero point was not set
correctly.
Reset zero point.
"FEATURE DISABLED"
Hitch recognition requested but no
hitch height set.
Perform "AUTO LEVEL" sequence to
establish hitch height.
Zero point not set.
Set zero point.
"LOW VOLTAGE"
Bad connection or wiring.
Discharged or bad battery.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
"OUT OF STROKE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
"EXTERNAL SENSOR"
Bad connection or wiring.
Replace or repair connection to rear remote
sensor.
"JACK TIME OUT"
System could not level in expected
time.
Check disposition of jacks.
"AUTO LEVEL FAIL"
Unsecured controller.
Voltage drop.
Check and secure controller placement.
Test battery voltage under load - charge or
replace.
"FUNCTION ABORTED"
User has aborted an automatic
leveling sequence.
Hit OK. Restart the sequence.
"HALL POWER SHORT"
Short circuit detected on one or
more of the jack hall effect power
lines.
Check harness and replace or repair.
OneControl Touch Panel or OneControl App Error Codes
(Rev. B)
NOTE: Faults can be cleared via the OneControl Touch Panel, OneControl App or Auto Leveling Control
Touch Pad. Most standard faults can be cleared from the Auto Leveling Control Touch Pad by
pressing "Retract All."
OneControl Touch Panel or OneControl App Error Codes
(Rev. A)
NOTE: Faults can only be cleared via the OneControl Touch Panel or OneControl App. The only exception is
when the Auto Leveling Control Touch Pad (Fig. 1) was used to abort an auto-sequence. In this case
the fault can be cleared by pressing any Auto Leveling Control Touch Pad button.
Rev: 06.28.18
Page 15
CCD-0001519
Special Jack Error Codes on OneControl Touch Panel or OneControl App
(Rev. B)
To clear the error codes:
1. Correct or otherwise repair the issue (see the Special Jack Error Codes chart).
NOTE: In order to clear the special jack error code the jacks need to perform a successful "Auto Retract."
2. Press "ENTER" to AUTO RETRACT. The jacks will retract until they reach the hard current limit.
3. The jacks are now “homed” and the special jack error code will be cleared.
NOTE: If the jacks do not retract, an error should display on the touch panel screen. This is typically caused
by wiring interruption.
Special Jack Error Codes
Touch Panel
Message
What's Happening?
What Should I Do?
***ERROR***
Left-Front Jack Fault
Right-Front Jack Fault
Left-Mid Jack Fault
Right-Mid Jack Fault
Left-Rear Jack Fault
Right-Rear Jack Fault
Error at a specific jack (left front,
right front, left middle, right middle,
left rear, right rear). Hall signal issue
(open, short, malfunction or loss
of communication); open or short
circuit between controller and motor.
Check harness connections
at controller and at jack.
Check harness for damage.
Check fuses at controller.
Repair or replace as necessary.
Clearing Faults From Auto Leveling Control Touch Pad
(Rev. B)
NOTE: Landing gear can still be extended/retracted in the "Special Jack Error Code" mode.
1. To clear most standard faults, press "Retract All."
2. To clear jack faults, press and hold "Retract All" until the jacks begin to retract.
NOTE: Three faults cannot be cleared from the Auto Leveling Control Touch Pad and must be addressed
from the OneControl Touch Panel or OneControl App: HALL POWER SHORT, BAD CALIBRATION and
EXTERNAL SENSOR.
Special Jack Error Codes on OneControl Touch Panel or OneControl App
(Rev. A)
To clear the error code:
1. Correct or otherwise repair the issue (see Special Jack Error Codes chart).
NOTE: In order to clear the special jack error code the jacks need to be "homed." In order to "home" jacks,
each jack must be able to retract a minimum of 6".
2. Extend all jacks to reach the 6" of minimum retract needed.
A. Press "FRONT" (Fig. 3B or Fig. 6B) to extend the front jacks (if required).
B. Press "REAR" (Fig. 3D or Fig. 6D) to extend the rear jacks (if required).
C. Press "LEFT" and "RIGHT" (Fig. 3A and Fig. 3C or Fig. 6A and Fig. 6C ) simultaneously to extend the
middle jacks (if equipped and required).
3. Press "ENTER" to AUTO RETRACT. The jacks will retract until they reach the hard current limit.
4. The jacks are now “homed” and the special jack error code will be cleared.
NOTE: If the jacks do not retract, an error should display on the touch panel screen. This is typically caused
by wiring interruption.
7 2
Summary of Contents for PINECREST