 SAFETY INFORMATION                                                                           

Important 

Every person involved with the installation, operation and maintenance of this device has to 

be  qualified  and  follow  the  instructions  of  this  manual.  Manufacturer  will  not  with 

responsibility for those operations which are not according to this Instruction.   

 

Verify that the voltage matches the rated voltage. 

 

When the voltage is 110V , Do not connect more than 10 lightings in total to AC mains 

power in one interconnected daisy chain   

 

When the voltage is 220V , Do not connect more than 20 lightings in total to AC mains 

power in one interconnected daisy chain   

 

Before using the fixture, check that all power distribution equipment and cables are in 

perfect condition and rated for the current requirements of all connected devices. 

 

Always ground (earth) the fixture electrically. 

 

Avoiding hit the Light when you are move or install the light. 

 

The  minimum  distance  between  light-output  and  the  illuminated  surface  must  be 

more  than  0.5  meters.  Keep  all  combustible  materials  (for  example  fabric,  wood, 

paper) at least 0.2 meters away from the fixture. 

 

Do not expose the fixture to rain or moisture. 

 

Avoid looking directly into the light source (especially those who suffer from epileptic 

fits) 

 

Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures 

higher than this.   

 

The Maximum surface temperature is 50°C 

 

When suspending the fixture above ground level, verify that the structure can hold at 

least 10 times the weight of all installed devices. 

 

Verify that all external covers and rigging hardware are securely fastened and use an 

approved means of secondary attachment such as a safety cable.   

To determine the power requirements for a particular fixture, see the label affixed 

 

to the back plate of the fixture or refer to the fixtures specifications chart. A fixture listed 

current rating is its average current draw under normal conditions. All fixtures must be 

directly powered off a switched circuit and cannot be run off a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer source voltage matches 

the fixtures requirement. Check the fixture or device carefully to make sure that if a voltage 

selection switch exists that it sets to the correct line voltage you will use. 

 

Warning! 

Verify that the voltage select switch on your unit matches the line voltage 

applied. Damage to your fixture may result if the line voltage applied does not match the 

voltage indicated on the voltage selector switch. All fixtures must be connected to circuits 

with a suitable Earth ground. 

 

 OPERATION INSTRUCTIONS     

                                                                                                   

 

The moving head is an LED wash light for onsite decoration purpose. 

 

Don’t turn on the fixture if it’s been through severe temperature difference like after 

transportation because it might damage the light due to the environment changes. So 

make sure to operate the fixture until it is in normal temperature. 

 

This light should be keep away from strong shaking during any transportation or 

movement. 

 

Don’t pull up the light by only the head, or it might cause damages to the mechanical 

parts. 

 

Don’t expose the fixture in overheat, moisture or environment with too much dust 

when installing it. And don’t lay any power cables on the floor. Or it might cause 

electronic shock to the people.   

 

Make sure the installation place is in good safety condition before installing the 

-02- 

03 

02 

Summary of Contents for Swift Aura 1925Z

Page 1: ...er Manual Swift1925Z Aura LED Moving Head Beam Wash Light User Manual Swift Aura LED Moving Head Zoom Light Swift 1925Z CE RoHS User Manual Please read this user manual before using this product Keep...

Page 2: ...very beautiful appearance Our Swift LED Moving Head is a very small and smart light But the brightness is very powerful It owns very good light beam and very wonderful color mixing effect As a SWIFT...

Page 3: ...nal covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable To determine the power requirements for a particular fixture see the labe...

Page 4: ...operate or any illegal operation like shock short circuit electronic shock lamp broke etc FEATURES AND SPECIFICATION Extremely small fast and powerful LED moving beam DMX Channels 14CH 27CH channels...

Page 5: ...You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below Address 31...

Page 6: ...DMX512 link use 3 5 pin XLR cable to link the unit together Mains input Connect to power supply Mains output Connect to supply power to the next unit Fuse T 6 3A Protect the unit from damage of the o...

Page 7: ...ton to view other DMX value Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Setting Enter MENU mode select Fixture Setting press ENTER button to confi...

Page 8: ...Select Cooling Mode press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select Auto Normal or Low Low speed Once selected press ENTER button to store Press M...

Page 9: ...isplay will show the error warning when the unit went wrong Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Language Select Language press ENTER button to con...

Page 10: ...he last menu or let the unit idle one minute to exit menu mode Zoom Reset Zoom Select Zoom press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to rese...

Page 11: ...he unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easil...

Page 12: ...1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast sl...

Page 13: ...set to zero These values need to be held for 5 seconds before feature is activated Values must be snapped to to function 2 Menu override setting unaffected by power off on 3 Value must be held for 3...

Page 14: ...een Green 0 100 CH12 000 255 Beam blue Blue 0 100 CH13 000 255 Beam white White 0 100 Only available when the fixture is set to RAW mode CH14 000 019 Beam CTC Color Temperature Control CTC disabled 02...

Page 15: ...Shutter open Strobe 9 sine wave fast slow Shutter open Strobe burst fast slow Shutter open CH10 000 255 RING 1 RED 0 100 CH11 000 255 RING 1 GREEN 0 100 CH12 000 255 RING 1 BLUE 0 100 CH13 000 255 RI...

Page 16: ...Macro12 Macro13 Macro14 Macro15 Macro16 Mocro17 CH26 000 255 COLOR MACRO SPEED CH27 000 019 020 255 Beam CTC Color Temperature Control CTC disabled CTC 10000K 2500K TROUBLE SHOOTING Following are a f...

Page 17: ...olor lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply...