SECTION 2: DESCRIPTION
AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 28
090010-OP_r0
See
Figure 2-14
. The standard instrument panel for the
Air N Arc 300 Series contains a volts/amps meter, welder
function switches (welder CC/CV toggle switch, and DC
charger/welder toggle switch), welder DC charge switch,
volt/amp manual adjustment dial, compressor ON/OFF
switch, air pressure gauge, fuel gauge/hour meter, weld
lead terminals, battery cable receptacle, generator
control ON/OFF switch, AC voltage outlets, AC overload
trip/reset buttons, and a fuel/hour meter gauge. In
addition, the panel contains function indicator lamps that
light to show various machine operation conditions.
2.6.1 VOLTS/AMPS METER
The
volts/amps meter
shows the amount of volts and/or
amp level while welding or boosting.
2.6.2 WELDER FUNCTION SWITCHES
The constant current (CC) or constant voltage (CV)
toggle switch
lets the operator choose the type of power
supply desired.
•CC Mode = Constant Amperage
•CV Mode = Constant Voltage
The three-position
DC charger/welder toggle switch
serves as the battery charge enabling switch, power-
enabling switch for welding, or the disabling (OFF) switch
for the welding function.
2.6.3 DC CHARGER MODE TOGGLE SWITCH
The three-position
DC charger mode toggle switch
lets
the operator choose the type of charge needed from 12V
center (default), 12V boost or 24V boost options. This is
a momentary switch; the lights will indicate the mode
selected.
2.6.4 VOLTS/AMPS MANUAL ADJUSTMENT DIAL
The
volts/amps manual adjustment dial
allows the
operate to manually increase or decrease the amount of
AC Voltage Outlets
2.6.10
page 30
Circuit Breaker Overload Trip/Reset
Buttons
2.6.11
page 30
Engine Control (ON/OFF/START)
Switch
2.6.12
page 31
Fuel Gauge/Hour Meter
2.6.13
page 31