SECTION 4: INSTALLATION
AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 38
090010-OP_r0
1. Drill four (4) 9/16” mounting holes in the
service body floor on a 19.25” by 44.375”
square pattern at the desired mounting
location. Ensure that all proper machine
clearances will be maintained.
2. For units without a fuel tank, follow these
steps:
• Mount the electric fuel pump at the
desired location on the service body
keeping it as close to the truck fuel tank
as possible. Mount the electric fuel pump
a maximum distance of 24 inches from
the bottom of the tank (
Figure 4-2
).
• Install 1/4” fuel line from the vehicle tank
to the 1/4” fuel filter under the hood of the
machine.
KEY
DESCRIPTION
A
47 inches
B
6 inches
C
65° angle
D
39 inches
E
66 inches
F
48 inches (panel remote-
mounted)
G
66 inches (panel mounted)
All length measurements are minimum
clearance parameter approximations.
Figure 4-1: Mounting Location Space Requirements
WARNING
Installation must adhere to the
safety precautions listed in the
Safety Section of this manual for
cooling and noxious fume
ventilation.
If mounting footprint is tighter
than the recommended minimum
requirements, consult the Vanair
Service Department for
application installation
recommendations.
NOTE
For set ups without a fuel tank where an
additional fuel pump is required, order
either of the following kits:
•Kit no. 032744 - Option for remote fuel
pump short run
•Kit no. 032745 - Option for remote fuel
pump long run