SECTION 5: OPERATION
AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 52
090010-OP_r0
The E indicates Electrode because some welding rods
are not electrodes. The 60 in 6010 indicates the tensile
strength in psi. 60,000 lbs.
The last 2 digits indicate position and polarity along with
what type flux. See
Table 5C
.
5.5 OPERATING THE GENERATOR
For a detailed account concerning the Generator Mode
ON and OFF functions, consult
Appendix B
,
Section
B.5.1
an
Section B.5.2
.
To operate the generator:
1. Start the engine.
NOTE
The Power System is designed to
support a multi-function project.
However, if the generator is operating at
a high percentage of its rated capacity,
and the welder and air compressor are
also being used, the resulting drop in
engine speed may produce a low voltage
condition that will damage the generator
and power tools being used.
TABLE 5C: WELDING ROD TYPE, POLARITY AND FLUX CODES
DIGIT
TYPE OF COATING
WELDING CURRENT
10
High cellulose sodium
DC+
11
High cellulose potassium
AC or DC+ or DC-
12
High titania sodium
AC or DC-
13
High titania potassium
AC or DC+
14
Iron powder titania
AC or DC- or DC+
15
Low hydrogen sodium
DC+
16
Low hydrogen potassium
AC or DC+
27
Iron powder iron oxide
AC or DC+ or DC-
18
Iron powder low hydrogen
AC or DC+
20
High iron oxide
AC or DC+ or DC-
22
High iron oxide
AC or DC-
24
Iron powder titania
AC or DC- or DC+
28
Low hydrogen potassium iron powder
AC or DC+