AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 4: INSTALLATION
090010-OP_r0
PAGE - 39
• Ensure that the lines do not make contact
with sharp edges, moving parts or
exhaust heat (consult
Appendix A,
Section A.6 Hose Installation Guide
for
assistance in running hose lines).
• Units must have a 70 micron fuel filter in
line before the pump.
3. Install the remote control panel (Optional) at
the desired location on the service body and
route the control trunk line to the location
where the unit will mount. Ensure that all
sharp edges that the trunk-line contacts are
shielded or grommeted, and that there are
no excessively sharp bends in the trunk-line.
Ensure the trunk line does not come in
contact with exhaust parts.
4.4 MACHINE PACKAGE MOUNTING
When determining package position on vehicle, be aware
of the minimum space requirements needed for cooling
and circulation requirements, and also package access
for performing maintenance (see
Figure 4-1,
and
Diagrams 4.5
and
4.6
).
1. Refer to
Figure 4-4
. Remove the truss screws
[
B
], nylon flat washers [
C
] in order to remove
access panel covers ([
A
] and [
K
]) found on
both side ends of the unit.
NOTE
Mounting brackets are available to space
panel off from truck body (
Figure 4-3
).
Contact Vanair.
KEY
DESCRIPTION
PART NUMBER
A
MOUNTING PATTERN WITH SPACER
(SPACER) A16738P
B
MOUNTING PATTERN WITHOUT SPACER
_
Figure 4-3: Mounting Pattern (with and without Spacer)
10.5”
5.0”
0.5Ø
10.5”
7.5”
0.5Ø
A
B
KEY
DESCRIPTION
A
FUEL PUMP
B
FUEL FILTER
C
FUEL TANK
D
24” CLEARANCE TO BOTTOM
OF FUEL TANK
Figure 4-2: Fuel Pump Clearance
A
B
C
D