AIR N ARC
®
200 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 6: MAINTENANCE
090019-OP_r0
PAGE - 91
PRECLEANER MAINTENANCE
Wash the precleaner element with warm water and
detergent. Rinse thoroughly and squeeze out excess
water (do not wring). Allow to dry before replacing.
AIR FILTER ELEMENT REPLACEMENT
1. Loosen the cover retaining knob [
A
] and
remove cover [
B
].
2. Remove and inspect the precleaner [
F
]: wash
or replace as necessary.
3. Clean area around the air cleaner element [
G
]
to prevent dirt and debris from entering the
engine.
4. Remove the element cover wing nut [
C
] and
element cover [
D
].
5. Remove the air filter element [
G
], and inspect:
replace as necessary.
6. Check the condition of the rubber seal [
E
] on
the air filter stud [
H
]. Replace if the seal is
worn, damaged, or questionable.
7. Reinstall the components in reverse order of
removal.
6.5.9.2 CHECKING THE ENGINE OIL
Refer to
Figure 6-21
. The engine oil level is checked
often and periodically as per the maintenance schedule
intervals suggested in
Section 6.3, MAINTENANCE
WARNING
Before performing maintenance or repair
operations on the machine, ensure that
all power has been removed and locked
out to prevent accidental start-up.
WARNING
Relieve pressure from the compressor
system before performing maintenance
on any components.
KEY
DESCRIPTION
A
COVER RETAINING KNOB
B
COVER
C
COVER WING NUT
D
ELEMENT COVER
E
RUBBER SEAL
F
PRECLEANER
G
AIR FILTER ELEMENT
I
H
AIR FILTER STUD
J
BODY
I
Order Air Filter Replacement Element no. 262722.
Figure 6-20: Engine Air Filter Maintenance
F
A
B
C
D
E
G
H
J