background image

 

 

15

 

 

Please follow the next steps to link the Indoor Siren 

using a Remote Control

1.

 

Connect the Siren to the Power Plug. 

2.

 

Press: the small black button located on one side of the Siren to turn the device in learning 
mode (all LED lights will turn to indicate that learning mode is activated). 

 

3.

 

Activate the Alarm System from the Remote Control by pressing emergency button “       ” 
then disarm the system from the remote control. 

4.

 

If the Siren was successfully synchronized to the system, the LED’s from the Siren will flash 
few times, if not please repeat the process.  

5.

 

Done! 

 

Please follow the next steps to link the Indoor Siren

 from the Alarm Host

1.

 

Connect the Siren to the Power Plug. 

2.

 

Press: the small black button located on one side of the Siren to turn the device in learning 
mode (all LED lights will turn to indicate that learning mode is activated). 

3.

 

Activate the Alarm System by pressing the Emergency Button located on the left side of the 
number  0  (zero),  once  the  alarm  has  been  triggered,    disarm  the  system  by  pressing  the 
Disarm Button located on the right side of the 0 (zero) then Enter Code: “888888” then press: 
“ ENT”. 

4.

 

If the Siren was successfully synchronized to the system, the LED’s from the Siren will flash 
few times, if not please repeat the process.  

5.

 

Done! 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WS-360

Page 1: ...WWW VALUESTORE US CustomerCare ValueStore Us Version 1 5 2014 Wireless Alarm System WS 360 With mini cellular module USER GUIDE...

Page 2: ...Disarm the system from Main Panel by SMS Wireless Keypad or Remote Control Zone number is displayed in the keypad s LCD screen when an alarm or trouble condition occurs on a sensor Supports GSM 2G 3G...

Page 3: ...3 Alarm System Overview Front side Back side...

Page 4: ...ard installation 1 How to setup phone numbers Page 16 STEP 4 Learn how to arm and disarm the alarm system 1 How to arm or disarm the system from a Main Panel Page 18 b Remote Control Page 19 c Mobile...

Page 5: ...ds please enter 132515 7 Press ENT 8 Done How to setup date Please follow the next steps 1 Press ENT 2 Enter Code 888888 this is the default password 3 Select Set Date use the arrows to find the optio...

Page 6: ...Zone Panic Buttons Smoke Detectors Gas Detectors 3 Perimeter Zone In this zone are linked all sensors that will be able to trigger the alarm system only when the system is Armed Home What sensors are...

Page 7: ...3 Select Program Sensor use the arrows to find the option in the menu 4 Press ENT 5 Delete the old record by pressing the arrow 6 Enter Zone Number 00 7 Press ENT 8 Enter Group Number Delete the old...

Page 8: ...ps to link the sensor to the system 1 Press ENT 2 Enter Code 888888 this is the default password 3 Select Program Sensor use the arrows to find the option in the menu 4 Press ENT 5 Delete the old reco...

Page 9: ...mming procedure Please follow the next steps to link the sensor to the system 1 Press ENT 2 Enter Code 888888 this is the default password 3 Select Program Sensor use the arrows to find the option in...

Page 10: ...w the steps Please follow the next steps to link the sensor to the system 1 Press ENT 2 Enter Code 888888 this is the default password 3 Select Program Sensor use the arrows to find the option in the...

Page 11: ...nge to zone number 12 because each zone supports up to 4 sensors the fifth Entry Sensor will be in zone number 12 and group number 0 and the sixth Entry Sensor will be in zone 12 and group 1 Note open...

Page 12: ...third Motion Detector will be in zone 21 and group number 2 the fourth Motion Detector will be in zone 21 and group number 3 now we change to zone number 22 because each zone supports up to 4 sensors...

Page 13: ...r to link the Outdoor Siren to the system it is needed to turn the Siren in learning mode then trigger the Alarm System and disarm Note Please check the backside of the Siren and find the green and re...

Page 14: ...ocated on the left side of the number 0 zero once the alarm has been triggered disarm the system by pressing the Disarm Button located on the right side of the 0 zero then Enter Code 888888 then press...

Page 15: ...please repeat the process 5 Done Please follow the next steps to link the Indoor Siren from the Alarm Host 1 Connect the Siren to the Power Plug 2 Press the small black button located on one side of...

Page 16: ...send notifications to your mobile phone Please follow the next steps to setup the phone numbers 1 Press ENT 2 Enter Code 888888 this is the default password 3 Select Auto Dialer s use the arrows to f...

Page 17: ...er to have the option Call by Phone functional you need to record a voice message in the panel by pressing and hold the button Record located in the back side of the panel once you finish the recordin...

Page 18: ...ven if the system is Disarm 1 From the Main Panel Please follow the next steps to arm the system from the panel 1 Press Arm Button or 0 2 Enter Code 888888 this is the default password 3 Select Arm Ho...

Page 19: ...S but you cannot Arm Home Please follow the next steps to arm the system by SMS 1 Send a SMS to cell phone number SIM card in the alarm panel with the next information 2 To Arm the system send the ala...

Page 20: ...any of these options as it is pre programmed for the optimum performance of the system These additional features are usually operated and modified only by expert users or installers IMPORTANT NOTICE...

Page 21: ...p to 60 minutes Please follow the next steps to disable the Sirens 1 Press SET 2 Enter Code 888888 this is the default password 3 Select Siren On Off use the arrows to find the option in the menu 4 Pr...

Page 22: ...r Code 888888 this is the default password 3 Select Arm Disarm Beep use the arrows to find the option in the menu 4 Press ENT 5 Choose OFF use the arrows to choose OFF 6 Press ENT 7 Done Please follow...

Page 23: ...rd 3 Select Upload Status use the arrows to find the option in the menu 4 Press ENT 5 Choose ON use the arrows to choose ON 6 Press ENT 7 Done 4 How To Change The Code Password This option is to chang...

Page 24: ...rd 3 Press ENT 4 Select Alarm History use the arrows to find the option in the menu 5 Press ENT 6 Use the arrows to review the alarm events 7 Status History This option will show you the arm disarm st...

Page 25: ...iguration process Panic Button 02 Gas 03 Smoke 04 General Sensors 12 Entry Sensors Door 04 Perimeter Sensors 10 Motion Detectors 11 Glass Breaker 06 Window Sensors 05 use this number for entry sensor...

Page 26: ...4 to choose the number according to what sensor are synchronized under the Zone Number you are modifying 10 Press ENT 11 Bypass Zone Choose YES of you wish to disable this Zone Number or NO if you wis...

Page 27: ...time in seconds from 00 to 59 seconds the default is 15 seconds 7 Press ENT 8 Done 10 How to modify Exit Delay This option is to modify the time before the system is fully armed by default the alarm s...

Page 28: ...art Zone use the arrows to find the option in the menu 4 Press ENT 5 Delete the old record by pressing the arrow 6 Enter Zone Number you wish to enable XX 7 Smart Sensor ON Select YES use the arrows t...

Page 29: ...29 SENSOR INSTALLATION LIST SENSOR NAME ZONE NUMBER GROUP NUMBER LOCATION NAME...

Page 30: ...30 Notes CustomerCare ValueStore us www ValueStore us...