SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

4

INSTALLATION

BEFORE OPERATION

1

1

2

3

4

5

WARNING

WARNING  :  To  avoid  possible  personal 
injury  or  equipment  damage,  a  register 
electrician  or  an  authorized  service 
representative should perform installation 
and  all  service.  Under  no  circumstances 

should  an  unqualified  person  attempt  to  wire  into 
utility circuit.
Give the generator at least two feet of space from 
any nearby wall to dissipate heat.

WARNING

WARNING:  do  not  use  a  pipe  carrying 
combustible  material  as  the  ground 
source. 

WARNING

WARNING : To avoid back feeding into utility 
system, isolation of the residence electrical 
system  is  required.  Before  temporary 
connection of a generator to the residence 
electrical  system  turn  off  the  main  switch. 

Before  making  permanent  connections  a  double 
throw  transfer  switch  must  be  installed.  To  avoid 
electrocution  or  property  damage,  only  a  trained 
electrician  should  connect  generator  to  residence 
electrical  system.  California  law  requires  isolation 
of the residence electrical system before connecting 
generator to residence electrical system.

A power line conditioner should be used when running 
one or more of the following solid state items:

• Garage door openers.

• Kitchen appliances with digital displays.

• Televisions.

• Stereos.

• Personal computers.

• Quartz clocks.

• Copy machines

• Telephone equipment

Other solid state equipment may require a power line 
conditioner,  for  more  information  contact  customer 
service. 
To avoid back feeding into utility systems, isolation of 
the residence electrical system is required.
Before  temporary  connection  of  the  generator  to  the 
residence system, turn off the main service disconnecting 
device.
If your generator is to be used as a stand – by power 
source  in  case  of  utility  power  failure,  it  should  be 
installed by a registered electrician and in compliance 
with all applicable local electrical codes.
Proper use requires that a double throw transfer switch 
be installed by licensed qualified electrician so that the 
building’s  electrical  circuits  may  be  safely  switched 
between utility power and the generator output; thereby 
preventing  back  feed  into  the  power  utility’s  electrical 
system.
Always follow local codes and regulations that apply to 
the installation of any item that concerns this product.
1. NFPA 70 – National Electrical Code.
2.  NFPA  37  –  Standard  for  Installation  and  Use  of 
Stationary Combustible Engines.
3. Agricultural Wiring handbook of Farm Standby Electric Power.

GROUNDING THE GENERATOR

The National Electric Code requires that this product be 
properly connected to appropriate earth ground to help 
prevent  electric  shock.  A  ground  terminal  connected 
to  the  frame  of  the  generator  has  been  provided  for 
this  purpose.  Connect  a  length  of  a  heavy  gauge  (12 
AWG min.)  bare cooper cable between the ground lug 
attached to the generator´s frame (identified with a label 
with the ground symbol- see figure below) and a cooper 
rod drawn 1 meter into the ground which should provide 
a  suitable  ground  connection.  However,  consult  with 
a local electrician to insure that local codes are being 
adhered to.

OPERATION vOLTAGE

CAUTION

C A U T I O N : Operating voltage and frequency 
requirements of all electronic equipment should 
be  checked  prior  plugging  them  into  this 
generator.  Damage may result if the equipment 

is not designed to operate /- 10% of voltage 
and  +/-  3  Hz  of  the  rated  values  marked  in  the 
generator´s  nameplate.  To  avoid  damage,  always 
have an additional no solid state load plugged into 
the generator if only solid state equipment (such as 
a television set) is used.  A power line conditioner is 
recommended for some solid state applications.

Summary of Contents for GT140MG2200RV

Page 1: ......

Page 2: ...ntially hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury...

Page 3: ...mpty Fuel shall not be stored near the generator Your generator should never be operated under these conditions Uncontrolled change in engine speed Electrical output loss Overheating in connected equi...

Page 4: ...nd by power source in case of utility power failure it should be installed by a registered electrician and in compliance with all applicable local electrical codes Proper use requires that a double th...

Page 5: ...ELECTRIC EXTENSIONS OR CORDS All generator loads will be connected from the control panel with extensions or cords with 3 prong grounded plug for connection to 127 volts outlet and 5 prong grounded pl...

Page 6: ...arting your generator you must install the following components Handles wheel kit and battery holder battery is not included handle installation 1 2 3 4 6 5 Unpack and inspect all parts to see if ther...

Page 7: ...d damage the Electronic Fuel Injection System CAUTION CAUTION Do not operate the generator with a low fuel level The EFI system could damage if the equipment doesn t have enough fuel All engines exhau...

Page 8: ...engine manual 1 2 3 4 5 6 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment Check the oil level and fuel Disconnect all electri...

Page 9: ...these instructions Replenish engine oil to upper level Drain gasoline from fuel tank line and carburetor Pour about one teaspoon of engine oil through the spark plug hole pull the recoil starter sever...

Page 10: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 10 GT150 WIRING DIAGRAM GT160 WIRING DIAGRAM...

Page 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 GT140 WIRING DIAGRAM...

Page 12: ...O THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACEANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATE...

Page 13: ...ANGE WITHOUT NOTICE 13 GENERATOR GENERAL ASSEMBLY DRAWING NOTE Some parts are listed and shown for illustration purposes only and not available individually as replacement parts NOTE Control panel may...

Page 14: ...necessary to run an engine in an enclosed area remove the exhaust fumes from the area with an exhaust pipe extension If you do not have an exhaust pipe extension do not use the generator in an enclose...

Page 15: ...Lea cuidadosamente y entienda el manual del operador antes de utilizar este producto Lea y entienda el manual de motor antes de su funcionamiento Siga todas las advertencias e instrucciones Conozca su...

Page 16: ...onductores tales como plataformas met licas o estructuras de acero Mantenga el generador limpio y libre de aceite barro o cualquier otro material extra o Los cordones de extensi n los cordones el ctri...

Page 17: ...cci n por la potencia nominal indicada en la hoja de especificaciones Siempre conecte la carga m s grande primero y luego agregue los dem s equipos uno por uno 7 REQUERIMIENTO DE VOLTAJE PRECAUCION Lo...

Page 18: ...tap n de pl stico del c rter por donde se le llena de aceite contiene la bayoneta con las marcas de lleno y vac o EL SENSOR DE BAJO NIVEL DE ACEITE Esta unidad esta equipada con un sensor de nivel ba...

Page 19: ...eg rese de que todas las piezas esten completas vea la secci n de Explosivo de Partes y Listado de Partes que est n al final de este manual Si alguna de las piezas no est o se encuentra en mal estado...

Page 20: ...de instalar la bater a quite la llave del Panel de control de su generador Monte sobre la base del generador el portabaterias y asegurelo con el tornillo rondana y tuerca como se indica en el dibujo...

Page 21: ...otor Utilice aceite SAE 30 Utilice un embudo para evitar el derrame de aceite Revisar el nivel de aceite con una bayoneta esta debe marcar lleno Coloque cuidadosamente el tap n de aceite para evitar q...

Page 22: ...revise las condiciones generales del generador revise que todas las piezas est n alineadas completas revise si hay cables da ados o alguna otra condici n que pueda afectar que el generador opere de m...

Page 23: ...estos f ciles pasos antes de llamar a la l nea directa de informaci n de servicio al cliente ALMACENAMIENTO A LARGO PLAZO Cuando el equipo generador no se est operando o est almacenado durante m s de...

Page 24: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 24 DIAGRAMA ELECTRICO GT160 DIAGRAMA ELECTRICO GT150...

Page 25: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 25 DIAGRAMA ELECTRICO GT140...

Page 26: ...CAMBIO SIN PREVIO AVISO 26 DIBUJO EXPLOSIVO DEL GENERADOR NOTE Some parts are listed and shown for illustration purposes only and not available individually as replacement parts NOTA El panel puede va...

Page 27: ...DISTRIBUIDOR REPRESENTAODAGARANTIAALCOMPRADORDEQUE STE EST CALIFICADO PARA HACER REEMPLAZO DE PIEZAS DE ESTE PRODUCTO DE HECHO EL FABRICANTE Y O DISTRIBUIDOR EXPRESAN QUE TODAS LAS REPARACIONES Y REE...

Page 28: ...ntiene mon xido de carbono un gas mortal Respirar mon xido de carbono puede provocar dolor de cabeza mareos n useas confusi n y eventualmente la muerte El mon xido de carbono es un gas inoloro incolor...

Reviews: