FOLLOW SAFETY INSTRUCTIONS

Carefully read all safety messages in this manual and 
on your product safety signs. Keep safety signs in good 
condition.
R e p l a c e   m i s s i n g   o r 
damaged  safety  signs. 
Be  sure  new  product 
components  and  repair 
parts include the current 
safety signs. 
Learn how to operate the 
product  and  how  to  use 
controls properly. Do not 
let anyone operate without instruction.
Keep  your  product  in  proper  working  condition. 
Unauthorized modifications to the product may impair 
the function and/or safety and affect product life.
If  you  do  no  understand  any  part  of  this  manual  and 
need assistance, contact your Distributor.

RECOGNIZE SAFETY INFORMATION

This is the safety alert symbol. 
When  you  see  this  symbol  on  your 
product or in this manual, be alert to the 
potential for personal injury.
Follow  recommended  precautions  and 
safe operating practices.

UNDERSTAND SIGNAL WORDS

A  signal  word--

DANGER,  WARNING  or  CAUTION

-

is  used  with  the  safety-alert 
symbol. 

DANGER

  identifies  the  most 

serious hazards.

DANGER or WARNING

 safety 

signs  are  located  near  specific  hazards.  General 
precautions are listed on

CAUTION

 safety signs. 

CAUTION

 also calls attention to safety messages in this 

manual.

SAFETY INFORMATION

WARNING

WARNING

The engine exhaust from 

this product, contains 

chemicals known to the 

State of California to cause 

cancer, birth defects or 

other reproductive harm.

This product contains 

one or more chemicals 

known to the State of 

California to cause cancer 

and birth defects or other 

reproductive  harm.

WORK IN A vENTILATED AREA

Engine  exhaust  fumes  can  cause 
sickness or death. If it is necessary 
to  run  an  engine  in  an  enclosed 
area,  remove  the  exhaust  fumes 
from the area with an exhaust pipe 
extension.
If you do not have an exhaust pipe 
extension, do not use the generator  
in an enclosed area.

D R A I N   G A S O L I N E   W H E N   S T O R I N G   Y O U R 
PRODUCT

Gasoline  stored  in  fuel  tank  can 
explode.
Never  store  your  product  with 
gasoline in the tank inside a building 
where  fumes  may  reach  an  open 
flame or spark.
Always  drain  gasoline  from  fuel 
tank  and  carburetor  bowl  when  storing  your  product.  
Allow engine to cool before storing.

HANDLE FUEL SAFETY-AvOID FIRES

Handle fuel with care: it is highly flammable. Do not refuel 
the product while smoking or when near open flame or 
sparks.
Always  stop  engine  before 
refueling  product.  Fill  fuel 
tank  outdoors.  Prevent  fires 
by  keeping  product  clean  of 
accumulated trash, grease and 
debris. Always clean up spilled 
fuel.

P R E P A R E  

F O R 

EMERGENCIES

Be  prepared  if  a  fire 
starts.
Keep a first aid kit and fire 
extinguisher handy.
Keep emergency numbers 
for  doctors,  ambulance 
service,  hospital  and  fire 
department  near  your 
telephone.

INSPECT YOUR GENERATOR

Be sure all covers, guards and shields are in place.
Locate all operating controls and safety labels.

SERvICE GENERATOR SAFELY

Before servicing your generator, disconnect all plug wires, 
and allow unit to cool down.
Service generator in a clean dry flat area. If applicable, 
block wheels to prevent unit from rolling.

WEAR PROTECTIvE CLOTHING

Wear  close  fitting  clothing  and  safety  equipment 
appropriate to the job.
Prolonged exposure to loud noise can cause impairment 
or loss of hearing.  Wear a suitable hearing protective 
device such as earmuffs or earplugs to protect against 
objectionable or uncomfortable loud noises.
Operating equipment safely requires the full attention of 
the operator. Do not wear radio or music headphones 
while operating equipment.

Summary of Contents for GT140MG2200RV

Page 1: ......

Page 2: ...ntially hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury...

Page 3: ...mpty Fuel shall not be stored near the generator Your generator should never be operated under these conditions Uncontrolled change in engine speed Electrical output loss Overheating in connected equi...

Page 4: ...nd by power source in case of utility power failure it should be installed by a registered electrician and in compliance with all applicable local electrical codes Proper use requires that a double th...

Page 5: ...ELECTRIC EXTENSIONS OR CORDS All generator loads will be connected from the control panel with extensions or cords with 3 prong grounded plug for connection to 127 volts outlet and 5 prong grounded pl...

Page 6: ...arting your generator you must install the following components Handles wheel kit and battery holder battery is not included handle installation 1 2 3 4 6 5 Unpack and inspect all parts to see if ther...

Page 7: ...d damage the Electronic Fuel Injection System CAUTION CAUTION Do not operate the generator with a low fuel level The EFI system could damage if the equipment doesn t have enough fuel All engines exhau...

Page 8: ...engine manual 1 2 3 4 5 6 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment Check the oil level and fuel Disconnect all electri...

Page 9: ...these instructions Replenish engine oil to upper level Drain gasoline from fuel tank line and carburetor Pour about one teaspoon of engine oil through the spark plug hole pull the recoil starter sever...

Page 10: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 10 GT150 WIRING DIAGRAM GT160 WIRING DIAGRAM...

Page 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 GT140 WIRING DIAGRAM...

Page 12: ...O THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACEANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATE...

Page 13: ...ANGE WITHOUT NOTICE 13 GENERATOR GENERAL ASSEMBLY DRAWING NOTE Some parts are listed and shown for illustration purposes only and not available individually as replacement parts NOTE Control panel may...

Page 14: ...necessary to run an engine in an enclosed area remove the exhaust fumes from the area with an exhaust pipe extension If you do not have an exhaust pipe extension do not use the generator in an enclose...

Page 15: ...Lea cuidadosamente y entienda el manual del operador antes de utilizar este producto Lea y entienda el manual de motor antes de su funcionamiento Siga todas las advertencias e instrucciones Conozca su...

Page 16: ...onductores tales como plataformas met licas o estructuras de acero Mantenga el generador limpio y libre de aceite barro o cualquier otro material extra o Los cordones de extensi n los cordones el ctri...

Page 17: ...cci n por la potencia nominal indicada en la hoja de especificaciones Siempre conecte la carga m s grande primero y luego agregue los dem s equipos uno por uno 7 REQUERIMIENTO DE VOLTAJE PRECAUCION Lo...

Page 18: ...tap n de pl stico del c rter por donde se le llena de aceite contiene la bayoneta con las marcas de lleno y vac o EL SENSOR DE BAJO NIVEL DE ACEITE Esta unidad esta equipada con un sensor de nivel ba...

Page 19: ...eg rese de que todas las piezas esten completas vea la secci n de Explosivo de Partes y Listado de Partes que est n al final de este manual Si alguna de las piezas no est o se encuentra en mal estado...

Page 20: ...de instalar la bater a quite la llave del Panel de control de su generador Monte sobre la base del generador el portabaterias y asegurelo con el tornillo rondana y tuerca como se indica en el dibujo...

Page 21: ...otor Utilice aceite SAE 30 Utilice un embudo para evitar el derrame de aceite Revisar el nivel de aceite con una bayoneta esta debe marcar lleno Coloque cuidadosamente el tap n de aceite para evitar q...

Page 22: ...revise las condiciones generales del generador revise que todas las piezas est n alineadas completas revise si hay cables da ados o alguna otra condici n que pueda afectar que el generador opere de m...

Page 23: ...estos f ciles pasos antes de llamar a la l nea directa de informaci n de servicio al cliente ALMACENAMIENTO A LARGO PLAZO Cuando el equipo generador no se est operando o est almacenado durante m s de...

Page 24: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 24 DIAGRAMA ELECTRICO GT160 DIAGRAMA ELECTRICO GT150...

Page 25: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 25 DIAGRAMA ELECTRICO GT140...

Page 26: ...CAMBIO SIN PREVIO AVISO 26 DIBUJO EXPLOSIVO DEL GENERADOR NOTE Some parts are listed and shown for illustration purposes only and not available individually as replacement parts NOTA El panel puede va...

Page 27: ...DISTRIBUIDOR REPRESENTAODAGARANTIAALCOMPRADORDEQUE STE EST CALIFICADO PARA HACER REEMPLAZO DE PIEZAS DE ESTE PRODUCTO DE HECHO EL FABRICANTE Y O DISTRIBUIDOR EXPRESAN QUE TODAS LAS REPARACIONES Y REE...

Page 28: ...ntiene mon xido de carbono un gas mortal Respirar mon xido de carbono puede provocar dolor de cabeza mareos n useas confusi n y eventualmente la muerte El mon xido de carbono es un gas inoloro incolor...