73
Suggested Con
ȴ
gurations
Not to scale
Note - Vertical 6-5/8” venting straight off the
2200 will pass by notched plenum without
offsetting the vent. If using 8” vertical venting,
a 20” deep cavity may not accomodate the
plenum. Adjust cavity depth accordingly.
Side wall outlets using LDK3
Front wall outlet using LDK1 or LDK4
LX2 Series
Note - When using LDK7, the discharge opening
must be located in the same room as the fireplace.
With LDK7
Ʉ
WARNING
The plenum duct kits are approved
for horizontal discharge ONLY. The
termination duct plates are approved
for vertical upward discharge ONLY. DO
NOT install plenum or termination plates
in
ȵ
oor or ceiling. DO NOT COVER OR
PLACE objects in front of or on top of air
outlet(s). AVOID locating outlet within
7 feet of the
ȵ
oor level as discharge air
temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
Appendix D - HeatShift
®
Installation