6.2.3 Window and ceramic fuel effect removal (All models).
-
Unscrew and remove the three spring loaded window fixing screws and bushes
from the base of the window frame (See figure 9). Keep the
screws and bushess in a safe place.
-
Gently swing the base of the window frame forward while
lifting the frame upward. The window should lift clear of the fire.
Put the window in a safe place away from your immediate work
area.
-
Carefully remove the ceramic fuel effect in its packaging. The
ceramic fuel effect base is a single piece. The individual
ceramic pieces are packed separately. Put them in a safe place
away from your immediate work area.
6.3 Preliminary checks.
6.3.1 Check ignition spark.
The pilot burner and electrode unit is at the left front corner of
the burner.
-
Push in the right hand control knob and turn
anticlockwise through the ignition position marked
and up to the pilot position marked
. A
spark should flash across from the pilot electrode to
the pilot burner hood. If there is no spark, check that
the spark gap is as shown in figure 10.
Page 20
©
GDC Group Ltd. 2014
INSTALLER GUIDE
Figure 10. Ignition check
Figure 9. Window
removal