83
© Vallox Oy - All rights reserved
0,00
1,00
2,00
3,00
4,00
5,00
0,50
1,50
2,50
3,50
4,50
0,0
10,0
20,0
30,0
40,0
100
140
180
0.100
0.050
0.020
A
B
C
D
Water flow dm³/s
Pressure loss kPa
0.100
53
0.075
31
0.050
14.5
0.040
9.5
0.025
4.0
0.020
2.7
PRESSURE LOSS MEASUREMENTS OF THE LIQUID SIDE
INPUT MEASUREMENTS
The measurements were taken using 55°C water. Other values have
been derived from these measurements.
A Thermal input, kW
B Difference in water temperature, °C
C Water flow dm³/s
D Air flow dm³/s
Vallox 245 MV liquid radiator t
a1
=15°C, t
f1
=55°C
Vallox 245 MV liquid radiator t
a1
=15
°C, t
f1
=70°C
0,00
1,00
2,00
3,00
4,00
5,00
7,00
6,00
0,0
20,0
40,0
60,0
0.100
0.050
0.020
100
140
180
A
B
C
D
0,00
1,00
2,00
3,00
4,00
5,00
7,00
8,00
6,00
0,0
20,0
40,0
60,0
0.100
0.050
0.020
100
140
180
A
B
C
D
Vallox 245 MV liquid radiator t
a1
=15
°C, t
f1
=85°C
0,0
20,0
30,0
10,0
0,00
1,00
2,00
3,00
0,50
1,50
2,50
100
140
180
0.100
0.050
0.020
A
B
C
D
Vallox 245 MV liquid radiator t
a1
=15
°C, t
f1
=40°C
TECHNIC
AL SPECIFIC
ATIONS
Summary of Contents for Vallox TSK Multi 80 MV