8. Pull the radiator and the support out of the unit (figures
6 and 7) and remove the quick connector of the radiator
wires.
CAUTION
Before removing the resistor from the unit, make sure it is
not hot.
9. The fan can now be cleaned in place. It is recommended
that the fan be cleaned in place, i.e. without attempting
to remove it.
10. To remove the fan for cleaning:
a. If necessary, remove the arm pins. Use pliers to press
the pins straight, so that they are easier to install back
later.
b. Push the fan gently upward (figure 9).
c. Pry the plastic lock to the right of the fan with a
screwdriver, for example (figure 10).
d. The fan falls downwards.
e. Pull the fan out of the unit (figure 11).
f. Disconnect the fan wire quick connector (figure 12).
The fan has now been removed for cleaning.
11. To reassemble the ventilation unit, follow the above
steps in reverse order.
TIP
When you re-install the temperature sensor, position it with
the tip upward and pointing at the wall in such a way that it
does not get squeezed between the bypass plate or lean
against the radiator frame.
12. Close the door. Ensure that the safety switch catch of the
door is touching the safety switch.
13. Plug the ventilation unit back into the mains.
The fan has now been checked and cleaned.