68
TECHNIC
AL SPECIFIC
ATIONS
Sound power level in the supply air duct
by octave band L
w
, dB
Sound power level in the extract air duct
by octave band L
w
, dB
Adjustment
position
100 %
78 %
67 %
59 %
49 %
37 %
28 %
18 %
9 %
100 %
78 %
67 %
59 %
49 %
37 %
28 %
18 %
9 %
Air flow dm
3
/s
54.6
50.4
43.9
38.7
31.3
25.1
18.8
13.8
8.1
62.8
56.9
50.3
45.0
37.9
32.1
26.2
19.1
13.7
Air flow m
3
/h
196.56 181.44 158.04 139.32 112.68
90.36
67.68
49.68
29.16 226.08 204.84 181.08
162
136.44 115.56
94.32
68.76
49.32
Medium
frequency
of the
octave
band Hz
63
57.6
57.4
54.1
52.8
50.2
47.3
44.9
40.7
42.3
51.0
50.0
47.6
45.5
43.4
38.2
34.0
31.6
30.3
125
60.4
59.3
57.3
55.6
53.7
50.0
51.1
47.8
40.5
57.8
57.0
54.5
51.9
49.2
48.0
44.7
44.1
40.4
250
64.0
62.3
61.0
59.9
58.5
55.1
51.2
45.9
34.9
55.3
53.9
52.7
52.1
48.6
47.9
43.5
37.6
28.7
500
66.2
64.3
61.8
60.8
55.2
50.0
45.5
39.5
30.1
51.0
50.2
48.3
49.4
40.8
36.2
30.8
25.3
17.6
1000
63.2
61.5
59.6
56.6
51.0
47.5
42.3
35.5
24.0
51.1
49.3
46.5
44.1
39.1
36.1
31.6
25.4
16.8
2000
58.8
56.9
54.3
51.3
47.4
41.9
34.4
23.9
17.8
40.1
38.4
36.8
35.3
29.9
27.7
21.3
13.9
12.2
4000
53.6
51.4
48.1
43.9
38.0
29.6
23.1
20.6
18.6
33.0
31.1
29.5
26.5
19.9
18.4
17.6
17.6
17.5
8000
36.5
33.4
29.6
26.5
24.3
23.3
23.1
23.1
23.2
23.5
23.2
23.1
23.2
22.9
22.9
22.9
22.9
22.9
L
W
, dB
L
WA
, dB(A)
70.6
68.9
66.8
65.2
62.0
58.1
55.4
50.9
45.2
61.3
60.2
58.1
56.7
53.0
51.5
47.6
45.3
41.2
67.5
65.6
63.3
61.1
57.0
52.3
47.6
41.5
32.5
54.1
52.7
50.6
49.7
44.5
42.7
38.0
33.5
28.9
Sound pressure level, in decibels (A) coming through the envelope from the room in which the unit is installed (10m
2
sound absorption)
ADJUSTMENT POSITION / AIR FLOWS (supply/extract)
Adjustment
position
100 %
78 %
67 %
59 %
49 %
37 %
28 %
18 %
9 %
Air flow dm
3
/s
54.0/61.4
49.3/55.8
43.9/50.1
38.1/44.0
31.5/37.3
25.1/30.9
19.4/25.1
13.4/18.6
8.0/13.1
Air flow m
3
/h
194.4/221.04
177.48/200.88
158.04/180.36
137.16/158.4
113.4/134.28
90.36/111.24
69.84/90.36
48.24/66.96
L
pA
, dB (A)
49.2
47.7
45.6
42.9
39.3
35.6
32.1
27.0
24.4
SOUND VALUES
Product titles
Vallox TSK Multi 80 MV
Vallox TSK Multi 80 MV EH
Vallox TSK Multi 80 MV EHX
Air volumes
Extract air
Supply air
0.071kW 0.5A 93 dm³/s 100 Pa
0.071kW 0,5A 76 dm³/s 100 Pa
Electrical connection
230 V, 50 Hz, ~8.8 A
Enclosure protection class
IP 34
Post-heating radiator (EH, EHX)
900 W, 3.9 A
Bypass duct heater
900 W, 3.9 A
Heat recovery
Cross-counter flow cell, η>80 %
Additional heating radiator (EHX)
900 W, 3.9 A
Fans
Supply air
Extract air
Efficiencies
Annual efficiency
Supply air efficiency
Specific Fan Power (SFP)
75% A+
82%
0.9kW/(m³/s) A
Filters
Supply air
Extract air
G4 and F7
G4
Heat recovery bypass
Motorized summer/winter damper
Weight
58.5 kg