17
© Vallox • We reserve the right to make changes without prior notice
EXPERT SETTINGS
SETUP WIZARD
FIREPLACE PROFILE
To make the Fireplace profile settings, proceed as follows:
1. The setup wizard for
Fireplace profile
opens.
2. Set the profile timer duration in minutes by using the
Plus
and
Minus
buttons.
3. The profile duration is now set.
4. Press the
Right arrow
button.
5. A display for setting the profile supply air fan speed opens.
6. Use the
Plus
and
Minus
buttons to set the supply air fan
speed of the
Fireplace profile
as a percentage of the
maximum output ratio.
TIP
It is recommended that a higher supply air fan speed be used in
the Fireplace mode to create overpressure in the ventilation zone.
Reducing the extract air fan speed is not recommended.
7. The Fireplace profile
supply air fan speed is now set.
8. Press the
Right arrow
button.
9. A display for setting the profile extract air fan speed opens.
10. Use the
Plus
and
Minus
buttons to set the extract air fan
speed of the
Fireplace profile
as a percentage of the
maximum output ratio.
11. The extract air fan speed of the
Fireplace profile
is now set.
12. Press the
Right arrow
button.
13. A display for setting the profile timer opens.
14. Use the
Plus
and
Minus
buttons to select whether the profile
timer function is used or not. The options are:
Ć
On
— When the timer is on,
the Fireplace profile
is used
only for the period specified by the timer.
Ć
Off
— When the timer is off, the
Fireplace profile
is
used until the profile is changed, either manually or
automatically by the Week clock.
15. The profile timer function is now set.
16. Press the
OK
button.
17. The
Fireplace profile
settings are now complete.