61
Troubleshooting
ICON5 / ICONX
VRI-iS Diagnostics (Continued)
Test Valve
Use to test valves for proper operation with water on
or off. This feature will turn all valves on and then turn
the valve number entered to off.
This setting will be maintained for 5 minutes or until
a different valve is commanded off. After 5 minutes
the control panel resorts back to the programmed
settings.
NOTE
• System should be running with water on to
test valve operation.
1. Push
Menu
,
Programs
,
and
VRI
to display the
VRI-iS screen. See Figure 61-1.
2. Push the
VRI-iS Diagnostics
button.
3. Select the
Valve #
field and set the valve number
using the numeric keypad.
4. Push the
Test Valve
button to display the Test
Valve screen.
5. When prompted to turn the valve off for 5 minutes
push the
Yes
button.
4
1
3
2
5
6
Figure 61-1 1. VRI-iS Diagnostics
2. Valve #
3. Test Valve
4. Yes
5. Test Valve Running Indicator
6. Stop Test Valve
Summary of Contents for VRI-iS
Page 2: ...2 This page was left blank intentionally...
Page 44: ...This page was left blank intentionally 44 Setup...
Page 50: ...50 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Field Install pn 9312421...
Page 51: ...51 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Wiring Schematic pn 0999334...
Page 52: ...52 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Field Install pn 9312419...
Page 53: ...53 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Wiring Schematic pn 0999346...
Page 82: ...82 Troubleshooting This page was left blank intentionally...
Page 102: ...102 Parts This page was left blank intentionally...