ICON10 / ICON1
Flow Meter Setup
• If a flow meter will be used in this application con-
tinue with step 1.
• If a flow meter will not be used in this application
continue with step 6.
To set the Flow Meter follow these steps:
1. Push
Menu
,
System
,
Data
, and
Flow/Hours
to
display the Flow/Hours screen. See Figure 38-1.
2. Select the
Flow Multiplier
field. See Figure 38-1.
3. Using the numeric keypad, enter the manufactur-
er’s recommended pulse multiplier value in either
gallons per pulse or liters per pulse, depending
on the unit of measure.
4. To enable the Low Flow Limit, select the
Low
Flow Limit
field to open the numeric keypad.
5. Push the
Low Flow Limit
field to enter the
minimum flow rate value into the numeric keypad
and push
Enter
to retain the value. The range is
1-999 gpm (lpm).
NOTE
• The Low Flow Limit will automatically be
enabled when a valid number is entered
into the keypad, this will be indicated
when the Low Flow Limit checkbox be-
comes checked. A value of 0 disables the
Low Flow Limit.
1
2
3
4
5
6
Figure 38-1 1. Menu
2. System
3. Data
4. Flow/Hours
5. Flow Multiplier
6. Low Flow Limit Field
38
Setup
Summary of Contents for VRI-iS
Page 2: ...2 This page was left blank intentionally...
Page 44: ...This page was left blank intentionally 44 Setup...
Page 50: ...50 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Field Install pn 9312421...
Page 51: ...51 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Wiring Schematic pn 0999334...
Page 52: ...52 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Field Install pn 9312419...
Page 53: ...53 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Wiring Schematic pn 0999346...
Page 82: ...82 Troubleshooting This page was left blank intentionally...
Page 102: ...102 Parts This page was left blank intentionally...