Operation
Valley ClassicPlus Control Panel
27
Stopping The Machine
Emergency Stopping
To stop the machine in an emergency situation, shut off any one of the following:
• Main Service Disconnect Switch from public power to the control panel. See Figure 27-1.
• Control Panel Main Disconnect Switch. See Figure 27-1.
• Any Tower Box Disconnect Switch. See Figure 27-1.
Stopping Under Normal Conditions
1. Press the START-STOP switch to the STOP posi-
tion. See Figure 27-2.
2. Turn the main disconnect switch to the OFF posi-
tion. See Figure 27-2.
3. Turn the pumping unit OFF (if not automatic).
4. If an engine generator set is utilized, place the
Engine Run/Start switch to the Start position for
the next start-up sequence.
!
WARNING
• DO NOT SHUT THE MACHINE OFF BY SLOW-
LY IDLING DOWN THE ENGINE GENERATOR
SET. THIS PRACTICE CAUSES LOW VOLT-
AGE AND WILL DAMAGE MACHINE COMPO-
NENTS.
• ALWAYS STOP THE IRRIGATION MACHINE
PRIOR TO SHUTTING DOWN THE ENGINE-
GENERATOR SET.