background image

-  8  -

g

!

!

WARNING! Connection to the power supply 

network must be made with a 230V~50Hz 

socket with an earthed contact. See attached 

technical data.

MACHINE DESCRIPTION (FIG.A)

1  Pump body

2  Coupling handle

3  Pump base with liquid suction

4 Delivery

5  Starting float

6  Power supply cable

7  Technical data label

8  Suction grid

SYMBOLS (FIG.B)

1   Technical  data

2  Double electric insulation

3  CE conformity mark

FIELD OF USE OF THE PUMP

High head multi-stage pump for clear water.

The submersible pump is suitable for suction

exclusively water where it is possible to im-

merse directly. It can be used in wells, tanks, 

containers, etc. where there is no direct con-

tact between people and water (it should not 

be used in swimming pools and similar, unless 

otherwise indicated). The pump, by means of 

the float switch, starts and stops automatically 

depending on the water level.

It is only suitable for clean water.

It is a high-pressure pump, see the following 

technical data and indications.

CONNECTION TO THE ELECTRIC POWER 

SUPPLY

The pump is equipped with a connection cable 

and plug. Connect the plug to a appropriate 

socket which must be equipped with an efficient 

earthed contact.

Check that the socket is efficient and that it has a 

protection device for over currents of at least 6 A.

 

WARNING! Always check that the cable 

and the plug are not damaged. Do not use the 

pump if the cable is damaged!

!

!

If the power cable is damaged, it must be 

replaced by the manufacturer, support service 

or qualified staff in order to avoid any dangers.

!

!

WARNING! Installation Standards

-  Always observe the values of ‘maximum immer-

sion depth’ and ‘maximum head’ shown in the 

specifications.

- Do not transport aggressive liquids or liquids with 

abrasive substances in a suspension.

- Protect the pump from freezing. 

- Do not operate the pump dry.

- Never hang up the pump by its water delivery 

hose, by the power supply cable or by the float.

- The pump must be resting on its base or 

hanging up using the special handle, always 

upright.

- In order to guarantee optimal operation of the 

pump, the bottom of the sump must be clean 

and free from mud. The mud could block the 

impeller when it dries inside, stopping the 

pump from working.

- Do not use the power cord for lifting and tran-

sporting the pump. 

- The plug should not be submerged. 

- Remove the power from the pump and di-

sconnect any possible plug from the mains 

before any maintenance, cleaning or moving 

operation.

- Use protective gloves for each operation on 

the pump. 

INSTALLATION

- Screw the connection onto the pump delivery 

(pos. 4).

- Fix the delivery hose onto the rubber holder.

WARNING! The outlet pressure of the pump is 

high, use a suitable hose and clamp.

- Immerse the pump in the liquid to draw using 

a rope tied to the handle.

- The power cord must be immersed for sud-

denly only necessary but not too tense. 

WARNING! Always check that the power cord 

does not interfere with the movement of the 

float.

- Connect the power supply cable to the socket.

The float switch allows the pump to be started 

and stopped automatically according to the 

Summary of Contents for ESP-INOX1101/3

Page 1: ...istruzioni d uso fornite WARNING Before using the machine read and understand the supplied safety instructions and operating instructions Elettropompa sommergibile ISTRUZIONI D USO Istruzioni original...

Page 2: ...2 NL VALEX 36015 SCHIO VI ITALY MADE IN P R C A B 1 1 6 5 7 3 1 4 2 8 2 5 15 25 35 40 10 20 30 45 NL VALEX 3 6015 SCHIO VI ITALY MADE IN P R C...

Page 3: ...NE DI CONFORMITA La ditta indicata in etichetta dichiara sotto la propria responsabilit che il prodotto ivi citato conforme ai requisiti essenziali di sicurezza e salute contenuti nelle seguenti diret...

Page 4: ...limentazione danneggiato deve essere sostituito dal produttore dal suo servizio assistenza o da personale qualificato al fine di evitare pericoli ATTENZIONE Norme per l installazione Rispettate sempre...

Page 5: ...camente la pompa con acqua pulita in particolare nella zona inferiore dove situata la griglia della girante Controllare ed eventualmente pulire le tubazioni di mandata Verificare la perfetta tenuta de...

Page 6: ...asata Pulire la griglia di protezione La pompa insabbiata Estrarre la pompa e farla revisionare La pompa non si spegne quando l ac qua scende L interruttore a galleg giante bloccato in alto Dare spazi...

Page 7: ...7...

Page 8: ...d it must be replaced by the manufacturer support service or qualified staff in order to avoid any dangers WARNING Installation Standards Always observe the values of maximum immer sion depth and maxi...

Page 9: ...iner in which the pump is immersed clean Check that the connection cable and the float cable are in perfect conditions In case of excessive deposits remove the impeller protection grille and eliminate...

Page 10: ...Clean the protection grille The pump is buried Remove the pump and examine it The pump does not switch off when the water goes down The float switch is blo cked up high Make enough space for its movem...

Page 11: ...11...

Page 12: ......

Reviews: