DuoPrint Series
Function Menu
10.15 Operating
Manual
55
7.12 Service Functions
NOTICE!
So that the distributor res. the manufacturer in case of service
can offer fast support the necessary information such as
selected parameters can be taken directly from the service
functions menu of the device.
Switch on the label printer and the display shows the main menu.
Press key
to access the function menu.
Press key
as long as you arrive the
Service functions
menu.
Press key
to select the menu.
Indication of label parameters in Volt.
A:
Indication of minimum value.
B:
Indication of difference between minimum and maximum value.
C:
Indication of trigger level. The value is ascertained while measuring
and can be changed.
Press key
to arrive the next menu item.
Indication of photocell level of the front printhead.
In case of problems while positioning or measuring of label, levels for
label photocell can be set manually. Make sure that a large hub as
possible (above the label >3 V, above the gap <1 V) is set.
Press key
to arrive the next menu item.
Indication of photocell level of the rear printhead.
In case of problems while positioning or measuring of label, levels for
label photocell can be set manually. Make sure that a large hub as
possible (above the label >3 V, above the gap <1 V) is set.
Press key
to arrive the next menu item.
PC1:
Indication of label photocell level of the front photocell in Volt.
PC2:
Indication of label photocell level of the rear printhead in Volt.
OPC:
Indication of ribbon save photocell level in Volt.
TR:
Indication of transfer ribbon photocell status
TR:
(either 0 or 1).
TR:
The first value stands for the front photocell and the second value
TR:
for the rear photocell.
H:
Indication of printhead position.
H:
0 = printhead down
H:
1 = printhead up
H:
The first value stands for the front photocell and the second value
H:
for the rear photocell.
Label parameters
Photocell configuration
(front printhead)
Photocell configuration
(rear printhead)
Photocell parameters