ALARM SYSTEM INPUT
Figure 22 illustrates a typical alarm system interface. When the alarm system is tripped, a tone will be
constantly sent to selected zones until the alarm is reset.
Required Programming: Type of Zone, step 17, (set the alarm system as Input #1, Tone Selection, step
27 (select a tone to be sounded when the alarm input is activated), Tone Routing, step 28 (route the tone
to in-facility paging zones).
Figure 22.
Alarm System Interfaces
COMPUTER MONITOR AND VISUAL MESSAGE DISPLAY
Figure 23 illustrates the Computer Monitor and Visual Display interface.
If a PC computer is connected to the RS-232 port of the Controller for the purpose of logging paging
activities, you will need to program the Controller to send signals to it, and turn ON/OFF the Attendant
Access, Telephone Access, and Night Bell signals that would trigger the monitor to log the event.
To communicate with a visual display, you will need to set the Computer Monitor option to Visual Display,
and enable the Input Monitor and Remote Monitor options for the interfaces, zones, and zone groups
you wish to monitor. You can also use the Phantom option of the Zone Output type parameter.
In addition, you will need to program the visual display with the messages you wish to display.
Required Programming: Computer Monitor, step 10 (set to Computer Monitor or Visual Display), Input to
Computer Monitor, step 11 (select monitor types).