17
947180
5 0 SET VOX DISCONNECT TIMING
The system will hang up on a page if no audio is detected for the programmed amount of time. The
default time is 30 seconds, but can be varied from 10 seconds to 60 seconds, in 10 second increments,
or can be disabled completely.
1. Dial
5 0
to select this option.
Hear a DOUBLE beep.
2. Dial the code to select a duration for the VOX Disconnect Timing:
0
to turn OFF
1
to select 10 seconds4 to select 40 seconds
2
to select 20 seconds5 to select 50 seconds
3
to select 30 seconds6 to select 60 seconds
Hear TRIPLE beeps.
3. To verify the duration of the VOX Disconnect Timing, dial
5 1
and repeat step 2 above.
5 2 ENABLE COMPUTER MONITOR
This option selects a device to be connected to the Controller RS-232 port, a computer monitor for log-
ging of all paging activity or a visual message display. The default setting is Computer Monitor.
By selecting Computer Monitor (the default option), the system is enabled to monitor activity on Atten-
dant Access, Telephone Interface, and Night Bell inputs. This feature requires that a PC computer be
connected to the RS-232 port of the Controller. Whenever the input becomes active, ASCII characters
will be sent out the RS-232 port (DB9 pin connector) to the computer. The ASCII characters will be inter-
cepted by a special software package in the computer that logs the time, date, input zone, type of activ-
ity, zone that was paged, and duration of the activity. All such input activity to the paging system can then
be viewed (and recorded) on the computer.
By selecting
Display
, the monitoring activity described above enables commands to be sent to a visual
message display where preprogrammed messages are displayed.
1. Dial
5 2
to select this option.
Hear a DOUBLE beep.
2. Dial the
0
to select Computer Monitor, or
1
to select Visual Display
Hear TRIPLE beeps.
3. To verify the status of this option, dial
5 3
and repeat step 2 above.
If a Computer Monitor or visual message display has been connected and Controller software loaded,
you will need to select the types of paging inputs to be displayed or recorded. See next programming
option “Input Computer Monitor.”