19
947180
5 8 SPECIFY ZONE MICROPHONE
This option allows you to specify that a zone microphone is attached to the Attendant Access interface.
When the Zone Microphone option is enabled (ON), the controller will wait for a zone to be selected from
the microphone keypad before it makes a page. When disabled (OFF), the controller reverts to its normal
(All Call) operation.
1. Dial
5 8
to select this option
Hear a DOUBLE beep.
2. Dial
0
to turn OFF, or
1
to turn ON
Hear TRIPLE beeps.
3. To verify the condition (OFF/ON) of the Zone Microphone option, dial
5 9
and repeat step 2 above.
GENERAL ZONE AND ZONE GROUP CONFIGURATIONS
General Zone and Zone Group Configurations are options that apply to selected zones or groups, not to
the entire system. The steps following Copy Command, describe each option.
1 2 COPY COMMAND
The COPY command can be used to copy the configuration of a zone that has already been optioned, to
one or more additional zones. This saves re-entering the same parameters over again, to duplicate the
parameters of an existing zone.
1. Dial
1 2
to activate COPY command.
Hear a DOUBLE beep tone.
2. Enter the zone number that you wish to copy from (i.e., 01).
Hear DOUBLE beep tone.
3. Enter the zone number of the beginning of the range of zones you wish to copy to.
Hear a DOUBLE beep tone.
4. Enter the zone number of the END of the zone range to be copied to.
Hear a TRIPLE beep tone.
Note:
Program the Controller using the physical zone number.
For example, to copy the parameters of zone 01 to all other zones, the range zone 02 to 56 would be
entered in this step and the next. To copy to a single zone (for example, 02) enter that zone number as
both the beginning and the end of the range (02 to 02). In this step, enter only the beginning zone of the
zone range.
6 0 ZONE MAP OPTION -- ASSIGNING ALIAS NUMBERS
Note:
Before doing this option, you MUST do “Define Length of ALIAS Numbers” (see Step 3).
Zone Map permits you to assign the dialing code, called the ALIAS zone code, that you will dial to
access a particular zone by telephone (i.e., instead of dialing 02 to make a page, you could dial 2202).
The factory default is NONE: no ALIAS numbers are pre-programmed. The zones are identified by their
2-digit Physical Zone Codes (01 thru 56 and groups 81-88) as the default condition.
Technical Manuals Online! - http://www.tech-man.com
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com