Table 4.
Input Zone/Group Configurations
ZONE MAP AND ZONE CONFIGURATION TABLES
1. Write a brief description of each zone.
For example, Lobby, Warehouse, Doorbell: Security Door, Fire alarm, etc.
2. Assign ALIAS Zone Numbers (optional).
An Alias Zone Number if the extension number (3 or 4 digits) you intend to dial to reach this zone. If an
ALIAS number is assigned to any zone, ALIAS numbers must be assigned to ALL zones.
3. Enter the Input or Output zone type.
Write an I-1, I-2, or an O to indicate the type of zone. I-1 means input priority level 1; I-2 means input pri-
ority 2 (the higher the priority zones get first access to the Controller). Input and Output here mean inputs
to, or outputs from, the Controller.
4. Fill in description of Output Zone.
See examples in step one. Refer to the Zone Map.
5. Enter the Type of Output.
The options are Audio/N.O., Mom. Open, N-C, Sys HS, Toggle, Phantom, or AA Ready.
6. For the other features listed for that zone, enter a Y (yes) or N (no) to implement those options.
7. Fill in description of Input Zone.
See examples in step one. Refer to the Zone Map.
8. Enter the Priority Level (1 or 2) for this zone.
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen For
Default
Activate Tone via
an Input Closure
To Select
To Verify
92
93
Double
Beep
Enter the input zone
number.
Double
Beep
0 – None
1 – Chime
2 – Siren
3 – Warble Siren
4 – Night Bell
5 – Fast Ring
6 – Steady Tone
7 – Door Bell
Triple Beeps
None
Tone Routing
To Select
To Verify
94
95
Double
Beep
Enter the input zone
number.
Double
Beep
Output zone/group
number
Triple Beeps
None
Audio Source
Enabled
To Select
To Verify
96
97
Double
Beep
Enter the input zone
number.
Double
Beep
0 – None
1 – AA
2 – T/R
Triple Beeps
None
Audio Routing
To Select
To Verify
98
99
Double
Beep
Enter the input zone
number.
Double
Beep
Output zone/group
number
Triple Beeps
None
*NOTES:
1.
Program the PagePac Plus using the ALIAS numbers, if optioned. Otherwise, use Physical zone/group numbers
2.
Exit the programming mode by dialing #
3.
The # key will terminate a digit string (i.e. Zone Numbers string)