9 Sensor specifications
77
9.3.1 PR-23-AC sensor model code
SANITARY COMPACT REFRACTOMETER for pipelines
Model and description
Model
PR-23 = Refractometer
PR-23
Sensor model
-A = 3-A Sanitary Standard 46-03 certified
-A
Sensor type
C = Compact type for pipeline installations
C
Refractive index range limits
-62 = R.I. 1.320–1.530 n
D
(0-100 Brix) Spinel prism
-62
-73 = R.I. 1.320–1.530 n
D
(0-100 Brix) Sapphire prism
-73
-74 = R.I. 1.260–1.470 n
D
Sapphire prism
-74
Process connection
-H = Sanitary 3A-clamp, 2½inch, insertion length 14 mm
(A)
-H
-E = Varivent
®
in-line access unit clamp DN65
-E
-N = Sanitary 3A-clamp, 2½inch, insertion length 14 mm, high pressure, 40 bar at 20°C
-N
-ZC = Sanitary I-line male (14 WI) 2½inch, insertion length 14 mm
-ZC
Sensor wetted parts material
SS = AISI 316 L
SS
HC = Alloy C276
(B)
Electrical classification
-GP = General purpose
-GP
-AX = ATEX and IECEx certified Ex II 3G, Ex nA IIC T4 Gc (up to zone 2) (T
amb
-20 ... +65°C)
-AX
-FM = FM certified Class I, Div.2, Groups A, B, C, D T6 (T
amb
-20 ... +45°C)
-FM
-CS = CSA certified Class I, Div.2., Groups A, B, C, D, T4 (T
amb
-20 ... +45°C)
-CS
-IA = ATEX and IECEx certified Ex II 1G, Ex ia IIC T4 Ga (up to zone 0) (T
amb
-20 ... +65°C
(C)
-IA
-IF = FM certified to US and Canadian standards Class I, Div.1, Groups A, B, C, D T4 (T
amb
-20 ...
+45°C)
(C)
-IF
Sensor housing
-AA = Anodized Aluminium
-AA
-SC = Stainless steel AISI 316
-SC
EHEDG option
-EH = EHEDG Type EL Class I Certified Model
(D)
-EH
Polishing option
-EP = Electropolished sensor wetted parts (RA 0.38µ, 15 µ inch)
(A)
(A)
For AISI 316 L / EN 1.4335 only
(B)
Includes gasket Teflon 2.5" and Ferrule in Alloy C
(C)
Available with STR Indicating Transmitter and IS isolator only
(D)
for -H, -E, -N options
Summary of Contents for K-PATENTS PR-23 Series
Page 1: ...IM EN PR23 v 2 00 Instruction Manual Vaisala K PATENTS Process Refractometer PR 23...
Page 2: ......
Page 4: ......
Page 17: ...2 Inline refractometer sensor 7 2 2 2 PR 23 mounting guide...
Page 26: ...16 PR 23 instruction manual...
Page 29: ...4 Prism wash systems 19 Figure 4 1 A prism wash system for steam non sanitary...
Page 30: ...20 PR 23 instruction manual Figure 4 2 A sanitary prism wash system for steam...
Page 32: ...22 PR 23 instruction manual Figure 4 5 Wiring for a prism wash system for steam...
Page 33: ...4 Prism wash systems 23 Figure 4 6 A prism wash system for high pressure water non sanitary...
Page 34: ...24 PR 23 instruction manual Figure 4 7 A sanitary prism wash system for high pressure water...
Page 35: ...4 Prism wash systems 25 Figure 4 8 Wiring for a prism wash system for high pressure water...
Page 40: ...30 PR 23 instruction manual...
Page 50: ...40 PR 23 instruction manual...
Page 72: ...62 PR 23 instruction manual...
Page 174: ...164 PR 23 instruction manual...
Page 179: ...11 Safe Drive 169 11 3 3 Safe Drive steam wash system parts...
Page 186: ...176 PR 23 instruction manual 11 4 2 Wiring Figure 11 9 PR 23 SD system wiring...
Page 204: ...194 PR 23 instruction manual Figure 11 19 Markings on the retractor handle...
Page 206: ...196 PR 23 instruction manual...
Page 218: ...208 PR 23 instruction manual...
Page 226: ...216 PR 23 instruction manual...
Page 230: ...220 PR 23 instruction manual...
Page 232: ...222...
Page 238: ...228...
Page 240: ...230...
Page 242: ...232...
Page 244: ...234...
Page 246: ...www vaisala com...