148
PR-23 instruction manual
10.3 Specifications
10.3.1 Indicating transmitter specifications
Display:
320x240 pixel graphical LCD with LED backlight
Keypad:
18 membrane keys
Current output:
Two independent current sources, 4-20 mA, max.
load 1000 Ohm, galvanic isolation 1500 VDC or AC
(peak), hold function during prism wash
Power:
AC input 100-240 VAC, ±10%, 50/60 Hz/30 VA,
optional 24 VDC, Overvoltage Category II, Pollution
Degree 2 (DTR), Pollution Degree 3 (sensor)
Alarms/Wash relays:
Two built-in signal relays, max. 250 V/3 A
Input switches:
Four switch inputs.
Current outputs:
Two current outputs configurable independently to
indicate process concentration or temperature of
either sensor.
Sensor connectivity, DTR:
One or two sensors can be connected to the
transmitter. Sensors independent of each other:
own parameter sets and usable in different
applications.
Sensor connectivity, STR:
Only one sensor can be connected to the transmitter.
Used with the Intrinsically safe sensor PR-23-...-IA.
Transmitter protection class:
Enclosure IP66, Nema 4X
Installation:
Transmitter indoor, sensor indoor/outdoor, relative
humidity 80% max
Indicating transmitter weight:
4.5 kg (10 lbs)
10.3.2 Interconnecting cable specifications
Cable:
IEC 61158-2 compliant two-wire cable:
two signal wires and shield
copper area 0.8 mm
2
(18 AWG)
cable resistance 24 Ohm/km (per wire)
cable attenuation 3.0 dB/km @ 28 kHz
Cable length:
Standard 10 m (33 ft), max. total length 200 m
(660 ft)
Note:
For information on the
intrinsically safe cabling
for PR-23-...-IA, see Sec-
tion 9.11.2 on page 140.
Summary of Contents for K-PATENTS PR-23 Series
Page 1: ...IM EN PR23 v 2 00 Instruction Manual Vaisala K PATENTS Process Refractometer PR 23...
Page 2: ......
Page 4: ......
Page 17: ...2 Inline refractometer sensor 7 2 2 2 PR 23 mounting guide...
Page 26: ...16 PR 23 instruction manual...
Page 29: ...4 Prism wash systems 19 Figure 4 1 A prism wash system for steam non sanitary...
Page 30: ...20 PR 23 instruction manual Figure 4 2 A sanitary prism wash system for steam...
Page 32: ...22 PR 23 instruction manual Figure 4 5 Wiring for a prism wash system for steam...
Page 33: ...4 Prism wash systems 23 Figure 4 6 A prism wash system for high pressure water non sanitary...
Page 34: ...24 PR 23 instruction manual Figure 4 7 A sanitary prism wash system for high pressure water...
Page 35: ...4 Prism wash systems 25 Figure 4 8 Wiring for a prism wash system for high pressure water...
Page 40: ...30 PR 23 instruction manual...
Page 50: ...40 PR 23 instruction manual...
Page 72: ...62 PR 23 instruction manual...
Page 174: ...164 PR 23 instruction manual...
Page 179: ...11 Safe Drive 169 11 3 3 Safe Drive steam wash system parts...
Page 186: ...176 PR 23 instruction manual 11 4 2 Wiring Figure 11 9 PR 23 SD system wiring...
Page 204: ...194 PR 23 instruction manual Figure 11 19 Markings on the retractor handle...
Page 206: ...196 PR 23 instruction manual...
Page 218: ...208 PR 23 instruction manual...
Page 226: ...216 PR 23 instruction manual...
Page 230: ...220 PR 23 instruction manual...
Page 232: ...222...
Page 238: ...228...
Page 240: ...230...
Page 242: ...232...
Page 244: ...234...
Page 246: ...www vaisala com...