70
Installation Instructions VRC 630 0020095108_00
7 Operating the controller
This is how to start the floor drying
Enter the start day
Day
for the appropriate heating
circuit to start the floor drying.
When the function is started, the boiler saves the cur-
rent time of the start. The day is changed exactly at this
time.
The
Temp.
parameter is determined by an internally
specified temperature profile (
¬ Table 7.18
). You can-
not set the
Temp.
parameter manually.
In the basic display of the controller,
Floor drying
is dis-
played for the corresponding heating circuit, instead of
the operating mode.
Wed 02.12.09
15:43
-3 °C
HK1
Heating
22.0°C
HK2
Floor drying
HK3
Eco
18.0°C
Cylinder
Auto
60.0°C
VRC 630
Ending floor drying
The function ends:
automatically when the last day of the temperature
profile has passed (
Day
= 29)
or
if you set the start day for the corresponding heating
circuit to 0 (
Day = 0
) in Menu
C9
.
>
–
–
–