Notes on the documentation 2
0020233500_01 auroCOMPACT Installation and maintenance instructions
7
2
Notes on the documentation
2.1
Observing other applicable documents
▶
You must observe all the operating and installation in-
structions included with the system components.
2.2
Storing documents
▶
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3
Validity of the instructions
These instructions apply only to:
Product types and article numbers
VSC D 146/4-5 150
0010020257
VSC D 146/4-5 150 (LL)
0010020258
VSC D 206/4-5 150
0010020259
VSC D 206/4-5 150 (LL)
0010020260
VSC D 146/4-5 190
0010020261
VSC D 206/4-5 190
0010020262
3
Product description
3.1
Serial number
The serial number is located behind a plate below the user
interface. It is also specified on the identification plate.
Note
The serial number can also be shown on
the display of the product (see the operating
instructions).
3.2
Information on the data plate
The data plate indicates the country in which the unit is to be
installed.
Information on the
data plate
Meaning
Serial number
For identification purposes; 7th to 16th
digits = product article number
VSC D…
Gas-fired boiler for heating and domestic
hot water generation
auroCOMPACT
Product designation
2H, G20 - 20 mbar
(2 kPa)
Gas group and gas connection pressure
as set at the factory
Kat.(e.g. II
2H3P
)
Approved gas category
Condensing techno-
logy
Efficiency class of the boiler in accord-
ance with EC Directive 92/42/EEC
Type (e.g. C
13
)
Permissible flue gas connections
PMS (e.g. 3 bar
(0.3 MPa))
Maximum water pressure in heating
mode
230 V 50 Hz
Electrical connection
–
Voltage
–
Fre-
quency
(e.g. 100) W
Max. electrical power consumption
IP (e.g. X4D)
Degree of protection against water
Heating mode
Information on the
data plate
Meaning
DHW mode
Pn
Nominal heat output range in heating
mode
P
Nominal heat output range in domestic
hot water mode
Qn
Nominal heat input range in heating
mode
Qnw
Nominal heat input range in domestic hot
water mode
N
L
Output characteristic figure in accord-
ance with the standard DIN 4708
Vs
Water content in the domestic hot water
cylinder
P
MW
Maximum water pressure in domestic hot
water mode
NOx
NOx class for the unit
D
Specific flow rate in domestic hot water
mode in accordance with EN13203-1
CE marking
Product complies with European stand-
ards and directives
Note
Check whether the product is compatible with the
gas type available on site.
3.3
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
3.4
DVGW mark
Applicability:
DVGW-labelled
The DVGW mark documents that the products comply with
all of the requirements of the DVGW VP 112 (test basis from
the German Association for Gas and Water Industry Asso-
ciation for granting the DVGW quality mark) in accordance
with the identification plate.