TECHNICAL DATA
15
Tolerances
Conductor system X-axis:
[mm] ± 3
Conductor system Y-axis:
[mm] ± 3
Conductor rail connectors Z-axis:
[mm] 0.7 + 1 per side
Current collectors X-axis:
[mm] ± 15 (DEAS ± 12)
Current collectors Y-axis:
[mm] ± 20
Operating conditions
Operating temperature
[°C] - 30 to + 55
Max. humidity at
[%]
ambient temperature 10°C to 40°C
98, non-condensing
Max. deviation of operating temperature
[K] 50
Flammability (insulator profile)
flame-retardant, self-extinguishing,
UL 94 V0
Application
Indoor installations
NOTICE!
UL certification
►
For design with UL certification, please consult the manufacturer.