technical characteristics
vacon
8
24-hour s358 (0)40 837 1150 • Email: [email protected]
2
2.2.3 575-volt drives
Mains voltage 575V, IP66, EMC N, 50-60 Hz, 3~
Converter
type
Motor shaft power and current
High overload
Low overload
50%
overload
50°C
[kW]
50%
overload
current
[A]
10%
overload
40°C
[kW]
20%
overload
current
[A]
Dimensions
W x H x D
[mm]
Weight
[kg]
S1
0002
0,5
1
1,1
1,7
221x306x166
6,35
0003
1,1
1,7
1,5
2,7
221x306x166
6,35
0004
1,5
2,7
2,2
3,9
221x306x166
6,35
0006
2,2
3,9
3,0
6,1
221x306x166
6,35
0009
3,0
6,1
5,0
9,0
221x306x166
6,35
0011
5,0
9,0
7,5
11,0
221x306x166
6,35
S2
0017
7,5
11,0
11,0
17,0
273x442x201
13,38
0022
11,0
17,0
15,0
22,0
273x442x201
13,38
0027
15,0
22,0
18,5
27,0
273x442x201
13,38
0032
18,5
27,0
22,0
32,0
273x442x201
13,38
S3
0041
22,0
32,0
30,0
41,0
286x513x314
22,68
0052
30,0
41,0
37,0
52,0
286x513x314
22,68
S4
0062
37,0
52,0
45,0
62,0
326x745x351
43,1
0077
45,0
62,0
55,0
77,0
326x745x351
43,1
0099
55,0
77,0
75,0
99,0
326x745x351
43,1
S5
a
a.
Enclosure class IP55
0125
75,0
99,0
90,0
125,0
414x1296x429
138,35
0144
90,0
125,0
110,0
144,0
414x1296x429
138,35
0192
110,0
144,0
132,0
192,0
414x1296x429
138,35
Summary of Contents for 50X
Page 1: ......
Page 5: ...introduction vacon 4 24 hour support 358 0 40 837 1150 Email vacon vacon com 1 ...
Page 23: ...receiving and installation vacon 22 24 hour support 358 0 40 837 1150 Email vacon vacon com 3 ...
Page 39: ...connections vacon 38 24 hour support 358 0 40 837 1150 Email vacon vacon com 4 ...
Page 101: ...vacon 50x parameters vacon 100 24 hour support 358 0 40 837 1150 Email vacon vacon com 7 ...
Page 132: ......