Floor Screed Machine HD 50
53
www.utiform.com
departamento.té[email protected]
Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
12.2
Operations prior to stoppage
Prior to carrying out any operation on the unit stop it and check that the circuit is depressurized.
1.-
Motor lubrication system. With the motor still hot, empty oil from the motor
following the specifications of this Manual, regardless of how long it has been in use.
2.-
Replace the filter element of the filter cleaning the vessel if it is not an integral
enclosed filter
3.-
Remove the covers of levers and grease with plenty of oil. If, when you remove the cover, there
is a copious amount of sludge, this is an indication that there is probably sludge in the interior, in which
case it would be advisable to clean them with cleaning oil. Fill the sump to the correct level, run the
motor until it reaches normal working temperature and keep it running for 15 to 30 minutes without
charge after which time it may be stopped and the oil can be drained off while it is still warm.
4.-
Fill the sump with conservation oil to the minimal level according to the attached instructions
and grease the levers
.
5.-
Empty the fuel circuit by loosening the drainage valves, fill both the injection pump and
the rest of the circuit with conservation oil SAE-10,do this manually with of the feed pump
until the circuit is completely full; next activate the starter motor so that the oil reached the
injectors and chambers without firing. Before, open the lateral cover of the pump (BOSCH) and
spray the rack with oil as well as the pistons, closing the cover correctly.
In addition, conservation oil may be mixed with fuel using 10% oil and running the motor for 10
minutes.
6.-
Empty the oil from the filters of the bath/oil and fill with conservation oil.
7.-
Loosen the belts and grease the necks of the belts. Prior to start up clean and connect according
to instructions.
8.-
Carefully close the aspiration conducts, the vent holes and the exhaust.
9.-
When the motor is delivered in these conditions it is necessary to indicate this fact clearly and
legibly and affected parts should be labeled.
10.-
Batteries, are delivered dry, with instructions for use attached.
11.-
For start up: Remove conservation oil from the motor, filer and injection pump; clean belt
necks, remove admission and exhaust plugs; and fill with the recommended operating oils.
Prior to starting the motor, turn the motor without firing a few times ensuring that everything turns
without problems. Once it is started, do not accelerate at the start but wait until the oil has filtered into every
part.