Floor Screed Machine HD 50
25
www.utiform.com
departamento.té[email protected]
Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
7.4 Mixing
The mixing process is as follows:
•
Raise the material reception cone
above the filling opening of the tank.
•
Fill the mixer tank halfway up
with aggregate (Z) (approx. 100 l).
•
Add aglutinante (B) according to
the manufacturer’s instructions.
•
Add necessary water (W).
•
Fill the mixing vessel with
aggregate(Z)
•
Check whether more water is needed and add if this is the case.
•
Prior to closing the mixing vessel with its lid, clean the rim of the tank with a brush or similar tool.
WARNING!
Only fill the mixing vessel 15 mm up to the lower rim of the filling spout of the mixing
vessel!
Failure to do so will considerably reduce the life time of the mixing vessel and its wearing parts.
7.5 Transport
The most common form of transport in the HD50/07 machine is in automatic mode but there is also a manual
operating process.
Automatic mode
There is a tap in the lower part of the control panel with automatic or manual position. Turn the tap to automatic
position and the compressor motor is ready to start.
Next the load-empty switch should be activated.
This switch situated on the panel activates or deactivates the Fuel Y1 electro valve , which loads or
empties the compressor. This switch is parallel to the magnetic contact of the mixer tank lid and the
procedure is as follows:
-
Close the cast iron cap of the vessel on the filling spout once the material has been mixed to the ideal
consistency.
-
Pull the lever (2) and press down until the lid of the tank seals hermitically
- Press the safety lever and activate the compressor load to the position ON, which activates the load-
empty switch so that the transport process can begin,
- Transport of the material is initiated when pressure forms in the vessel so that this same pressure causes
the first material to be pushed out of the tank
- As air enters when the material leaves the vessel, the material is transported through the transport hoses
by a jam system
.
Never open the cap if it is under pressure!
4
3
2