X2-3232: Modular Matrix Switcher 32x32
U.T.E. electronic GmbH & Co. KG
26
www.ute.de
6. RS232 Control
6.1. RS232 Communication Port
Except the front control panel and IR remote, the matrix can be controlled by far-end
control system or through the Ethernet control via the RS-232 communication port.
This RS-232 communication port is a female 9- D connector. The definition of its pin
layout is shown in the table below.
No.
Pin
Function
1
N/u
Unused
2
Tx
Transmit
3
Rx
Receive
4
N/u
Unused
5
Gnd
Ground
6
N/u
Unused
7
N/u
Unused
8
N/u
Unused
9
N/u
Unused
6.2. RS232 Control Software
When the matrix connects to the RS232 port of a computer with control software, users
can control it by that computer. To control the switcher, users need to use RS232 control
software.
6.2.1. Installation/ uninstallation of RS232 Control Software
⚫
Installation:
Copy the control software file to the computer connected with the
Transmitter.
⚫
Uninstallation:
Delete all the control software files in corresponding file path.
6.2.2. Basic Setting
Connect the matrix to all input devices and output devices needed, then connect it to a
PC which is installed with RS232 control software. Double-click the software icon to run
this software. Please refer the software
CommWatch.exe
as example. The icon is
shown as below: