2GM
1-5-17
Causes
Check procedures/corrective measures
1. Dirty or flawed main charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
(5) A white line appears
longitudinally.
Causes
1. Dirty or flawed main charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
(3) Image is too
light.
(4) Background is visible.
Causes
1. Insufficient toner.
2. Deteriorated developer.
3. Dirty or deteriorated drum.
Causes
Check procedures/corrective measures
1. Insufficient toner.
2. Deteriorated developer.
3. Dirty or deteriorated drum.
Causes
1. Deteriorated developer.
Causes
Check procedures/corrective measures
1. Deteriorated developer.
Replace the process unit.
If the add toner indicator lights, replace the toner container.
Replace the process unit.
Replace the process unit.
Replace the process unit.
Replace the process unit.
Replace the process unit.
Clean the shading plate.