![Utax CD 1018 Service Manual Download Page 109](http://html.mh-extra.com/html/utax/cd-1018/cd-1018_service-manual_1064812109.webp)
2GM
1-6-16
10. Remove the main PWB (see page 1-6-10).
11. Remove the screw and then remove the grounding plate.
12. Remove the screw and then remove the feed clutch.
13. Remove three stop rings.
14. Remove MP feed clutch (gear), feed clutch (gear), and registration clutch (gear).
Figure 1-6-19 Removing the clutches
Stop ring
Stop ring
Stop ring
MP feed clutch (gear)
Feed clutch (gear)
Feed clutch
Registration clutch (gear)
Screw
Screw
Grounding
plate