DRIVE PROGRAMMING 4-31
M01P48 TIME IN PRESET 2
Enter a value to define the time the auto preset sequencer
stays in “PRESET 2” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P49 TIME IN PRESET 3
Enter a value to define the time the auto preset sequencer
stays in “PRESET 3” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P50 TIME IN PRESET 4
Enter a value to define the time the auto preset sequencer
stays in “PRESET 4” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P51 TIME IN PRESET 5
Enter a value to define the time the auto preset sequencer
stays in “PRESET 5” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P52 TIME IN PRESET 6
Enter a value to define the time the auto preset sequencer
stays in “PRESET 6” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P53 TIME IN PRESET 7
Enter a value to define the time the auto preset sequencer
stays in “PRESET 7” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M01P54 TIME IN PRESET 8
Enter a value to define the time the auto preset sequencer
stays in “PRESET 7” (as shown by M01P44), when
parameter M01B42 is set to 1.
R-W
Range: 0 to 3276.0 Sec
Default: 20.0
M02P01 POST-RAMP REF
Frequency reference after the effects of ramps and normal
currents limits.
R-O
Range: ±M01P06 Hz
Default: 0.0
M02P02 RAMP MODE
Select from:
STD RAMP
[0]
Standard ramp
FAST RAMP
[1]
Fast ramp
The Ramp Modes parameter M02P02 controls deceleration
ramps only. The settings are as follows:
Setting
Description
0 STD RAMP
Standard ramp
1 FAST RAMP
Fast ramp
Mode 1 – Fast mode
The ramp falls at the programmed deceleration rate
subject only to the current limits programmed.
This mode is normally used when an AC Regen or braking
module is used.
R-W
Range: [0] STD RAMP
[1] FAST RAMP
Default: [0] STD RAMP
M02P03 ACCEL RAMP 1
Acceleration ramp rate is expressed as the time for the
R-W
Range: 0.1 to 3276 s/100Hz
Default: Size 0: 30.0 sec
Summary of Contents for PHOENIX EX
Page 1: ...INSTRUCTION MANUAL PHOENIX EX 3 TO 3500 HP VECTOR AC DRIVE ...
Page 12: ...1 8 INTRODUCTION END INTRODUCTION SECTION ...
Page 28: ...2 16 INSTALLATION AND WIRING Figure 2 3 Recommended Power Wiring ...
Page 32: ...2 20 INSTALLATION AND WIRING Figure 2 5 Control Logic and Signal Wiring ...
Page 56: ...Figure 4 2 Menu 1 Frequency Reference Limits and Filters 4 2 MENU AND PARAMETER DESCRIPTION ...
Page 57: ...Figure 4 3 Menu 2 Ramps MENU AND PARAMETER DESCRIPTION 4 3 ...
Page 58: ...Figure 4 4 Menu 3 Speed Input and Speed Loop 4 4 MENU AND PARAMETER DESCRIPTION ...
Page 59: ...MENU AND PARAMETER DESCRIPTION 4 5 Figure 4 5 Menu 4 Current Limits Torque Flux Control ...
Page 60: ...4 6 MENU AND PARAMETER DESCRIPTION Figure 4 6 Menu 5 Motor Control ...
Page 61: ...MENU AND PARAMETER DESCRIPTION 4 7 Figure 4 7 Menu 6 Operational Modes ...
Page 62: ...Figure 4 8 Menu 7 Analog Inputs and Outputs 4 8 MENU AND PARAMETER DESCRIPTION ...
Page 66: ...4 12 MENU AND PARAMETER DESCRIPTION Figure 4 12 Menu 11 Miscellaneous ...
Page 68: ...4 14 MENU AND PARAMETER DESCRIPTION Figure 4 14 Menu 12 Open Loop Brake Function 2 of 5 ...
Page 69: ...MENU AND PARAMETER DESCRIPTION 4 15 Figure 4 15 Menu 12 Closed Loop Brake Function 3 of 5 ...
Page 70: ...4 16 MENU AND PARAMETER DESCRIPTION Figure 4 16 Menu 12 Closed Loop Brake Function 4 of 5 ...
Page 71: ...MENU AND PARAMETER DESCRIPTION 4 17 Figure 4 17 Menu 12 Closed Loop Brake Function 5 of 5 ...
Page 73: ...Figure 4 19 Menu 14 PID Control Loop MENU AND PARAMETER DESCRIPTION 4 19 ...
Page 74: ...Figure 4 20 Menu 15 Position Control 1 of 2 4 20 MENU AND PARAMETER DESCRIPTION ...
Page 75: ...MENU AND PARAMETER DESCRIPTION 4 21 Figure 4 21 Menu 15 Position Control 2 of 2 ...
Page 76: ...Figure 4 22 Menu 17 2nd Motor Parameters 4 22 MENU AND PARAMETER DESCRIPTION ...
Page 153: ...APPENDIX A 3 Standard Drive with Manual Bypass Setup Diagram 2 of 2 ...
Page 155: ...APPENDIX A 5 Interconnect for Option Boards 3000 4040 120 3000 4050 120 ...
Page 156: ...APPENDIX A 6 Isolated Communication Card P N 3000 4135 with Jumper on Position 1 1 of 3 ...
Page 157: ...APPENDIX A 7 Isolated Communication Card P N 3000 4135 with Jumper on Position 2 2 of 3 ...
Page 158: ...APPENDIX A 8 Isolated Communication Card P N 3000 4135 3 of 3 Mounting Diagram ...
Page 162: ...APPENDIX A 12 Digital Encoder Card P N 3000 4140 1 3 of 3 Mounting Diagram ...
Page 164: ...APPENDIX A 14 I O Expansion Board 3000 4150 2 of 2 Mounting Diagram ...
Page 167: ...APPENDIX A 17 Digital Encoder 2 3000 4160 Page 3 of 3 Mounting Diagram ...
Page 168: ...APPENDIX A 18 THIS PAGE INTENTIONALLY LEFT BLANK ...