DS1092-121
94
4.5.5.7
ALARM PROGRAMMING submenu of FUNCTION PROGRAMMING menu
The menu allows to select the alarms that can be activated by the alarm board present in the POWER BOX or the
alarms present on a remote additional board.
Option
Value
Explanation
CHANNEL NUMBER
1/16
This option allows to select the alarm contact to be activated. 16
alarm contacts are available only using two alarm cards.
LABEL EDIT
This operation allows to give a name to the stored alarm contacts.
Press twice IRIS+ to display the screen where it is possible to give
a name to the selected contacts.
LABEL DISPLAY
ON/OFF
If set in ON, this option allows to display on the monitor the
previously stored name of the alarm contact that became active
after an event.
ACTION SETUP
Select this option and press the button IRIS+ to go to the
respective submenu, where it is possible to set the activation
parameters (see below).
CHANNEL ENABLE
ON/OFF
If set in ON, this option enables the previously described
functions.
ALARMS PROGRAMMING
1 Channel Number 1
2 Label edit -----
3 Label Display ON
4 Action Setup
5 Channel Enable ON
Summary of Contents for Easy Dome IV 1092 Series