DS1092-121
80
The following examples show how to program the free presets and recall them:
Example: programming preset number 32
1. Position the camera in a certain pan, tilt and zoom configuration.
2. Enter the command
32 + ENTER.
3. The setting is saved and the message “
Stored
” appears.
From this moment onwards, simply enter the command
CALL + 32 + ENTER
to move the camera to the preset
position.
e
Important note:
The saved value will be written over if the setting is reprogrammed.
The presettings are saved in a permanent memory area of the camera where they are maintained also when power is
disconnected. However, restoring default settings will delete all preset values.
Caution
. The presettings store the coordinates according to an angular reference system. Therefore, the reference
system zero point may become misaligned with the camera mechanics after prolonged use of the tilting and panning
functions. Minor inaccuracies in preset positions may occur. In this case, calibrate the angular coordinate system using
the {dome reset} command. This calibration is automatically run when the camera is switched on.
4.5
FUNCTION PROGRAMMING MENU
Use the following 1092/693-694 control panel command to access the function programming menu.
SHOT + 95 + ENTER
At this point, if no password is required for access, the following first level menu will appear on the screen:
Otherwise, if a password is required, the following prompt will appear.
EASY IV --------
1 Language English
2 Dome Information
3 Display Options
4 Control Options
5 Camera Options
6 Function Programming
7 Date/Time
8 System Setup
PLS enter the password
------------