DS1092-121
85
CAMERA EXPOSURE submenu of CAMERA OPTIONS menu
Option
Value
Explanation
AUTO
In this mode:
o
The shutter opening time cannot be set and is
automatically adjusted.
o
Autoiris opening is automatically adjusted.
o
Gain control is automatic (AGC ON).
SHUTTER
In this mode:
o
The shutter opening time may be varied as
programmed in the
“LOW LIGHT LIMIT
” menu.
o
Autoiris opening is automatically adjusted.
o
Gain control is automatic (AGC ON).
IRIS
In this mode:
o
The iris opening time is fixed to 1/50 second.
o
The autoiris opening is manually varied in the
“IRIS LEVEL
” menu.
o
Gain control is automatic (AGC ON).
MANUAL
In this mode:
o
The shutter opening time may be varied as
programmed in the
“LOW LIGHT LIMIT
” menu.
o
The autoiris opening is manually varied in the
“IRIS LEVEL
” menu.
o
AGC gain control is variable as programmed in
the
“AGC LEVEL”
menu.
All items may be accessed in this mode.
AE MODE
BRIGHT
In this mode:
o
The iris opening time is fixed to 1/50 second.
o
The autoiris opening is manually varied in the
“BRIGHT LEVEL”
menu.
o
Gain control is off (0 dB).
SLOW SHUTTER
ON/OFF
This function, if enabled (ON), increases the dome
sensitivity in poor lighting conditions.
SHUTTER SPEED
1 / 10000
Active only if AE MODE in MANUAL or SHUTTER. This
option allows to adjust manually the iris opening speed, by
selecting one of the values included in the indicated
range.
IRIS LEVEL
IRIS- / F22
Active only if AE MODE in MANUAL or IRIS.
Manual iris adjustment (parameter F).
It is used to manually set the iris opening time.
CAMERA EXPOSURE
1 AE Mode Shutter
2 Slow Shutter ON
3 Shutter Speed OFF
4 Iris Level Auto
5 AGC Level Auto
6 Bright Level Auto
7 Spot AE OFF
8 WDR OFF
Summary of Contents for Easy Dome IV 1092 Series
Page 115: ...DS1092 121 115...