33
DS1168-013C
SE -
Pedestrian electrical lock with capacitance discharge actuation negative
SE +
Pedestrian electrical lock with capacitance discharge actuation positive
(*)
Terminals present only on door unit Ref. 1083/39.
2.1.3 DESCRIPTION OF THE WIRES FOR CONNECTING DEVICE TO SURVEILLANCE CAMERAS
(FEATURE AVAILABLE ONLY ON DOOR UNIT REF. 1083/39)
A wire is provided with the product for connecting the door unit, via the connector (16) to and the surveillance
camera control device ref. 1083/69, for managing multiple cameras.
The camera control device Ref. 1083/69 must be set to default configuration (default setting).
Green wire (R)
Black wire (T-)
Yellow wire (T+)
R
Surveillance camera device reset: green wire
T- Surveillance camera control device reference (earth): black wire
T+ Surveillance camera device control: yellow wire
2.1.4 ADJUSTING THE SPEAKER VOLUME
The sound levels of the audio door unit Ref. 1083/38 and /39 or audio-video door unit Ref. 1083/48 are calibrated
at the factory so that they do not have to be changed in most installations.
Use a screwdriver to adjust the speaker volume (present on the back of the door unit), if required.
2.1.5 DDA (Disability Discrimination Act) LED ACTUATION SYSTEM STATUS INDICATION
The system state is shown by the following indications which appear on the door unit front:
a) call in progress: LED on green and voice message “CALL IN PROGRESS”;
b) line engaged: LED on red and voice message “THE LINE IS BUSY”;
c) off-hook waiting time expired: voice message “THE USER IS NOT ANSWERING”;
d) conversion in progress: LED on orange;
e) door open: LED
green and “THE DOOR IS OPEN” voice message.
The voice messages are possible if the audio-video door module Ref. 1083/48 or the audio door unit (Ref.
1083/38 and /39) is connected to the ILA and voice synthesis module Ref. 1168/48.
2.1.6 PEDESTRIAN LOCK ACTUATION
The door unit has two terminals for managing the pedestrian door lock (SE+ and SE-). The electric lock is operated
in the following cases:
•
whenever the hall button is pressed (terminals PA, CT);
• when a door open command is received from an apartment station according to the configuration (“
FREE” or
“PRIVACY”).
• After recognising:
a. a valid code entered on keypad module Ref. 1168/46;
b. a valid transponder key swiped in front of the proximity reader module Ref. 1168/45.
2.1.7 GARAGE GATE LOCK ACTUATION (GATE)
The audio and audio-video door units have two terminals (SE2) connected to the contacts of a normally open
relay which can be used to control
a gate opening control unit (*). The relay is operated for 1 second in the same
cases as described in the previous chapter.
(*) The relay is NOT suitable to control direct power loads and can only be used as control relay.