4 CONNECTION BLOCK DIAGRAM
4.1
BASIC ONE-HOUSEHOLD SYSTEM
Apartment 01
4
3
2
1
POE
MAX
POE Active
POE Fault
PWR
POE Ports
6
1
3
4
2
5
100M
10M
On = Link, B
link =
Act
7
8
LAN
NC
OUT 1
C
REL.
FW:
PB1
PB2
V-
V+
DECODIFICA
SPEC
IALE P
ER CA
T 5
SPECIA
L DECODER
FOR CA
T 5
NO
NO
OUT 2
C
NC
Light 02
Light 01
PoE
PoE
PoE
PoE
A
B
C
OP4
OP6
OP5
110-230 Vac
110-230 Vac
2
2
2
2
2
OP6
OP5
OP8
2
2
OP3
OP2
OP1
OP7
110-230 Vac
110-230 Vac
OP9
Internet
4.2 DISTANCES
For connections between the various IP devices, the maximum permissible distance is 100m - the distance
de
fi
ned by the standard IEEE802.3 for Fast Ethernet networks (100Mbps).
To ensure longest-range monitor operation, the cable must be a class 5e device and the twisted pairs’
cross section must be AWG24.
The maximum resistance of the individual wires must not exceed 10ohm/100m.
The cable must be up to the following standards:
-
EIA/TIA
568-B.2
-
EN50288
3-1
-
IEC
61156-5
The connection between the monitor and PoE switch must be ensured by a single cable without any extra
patch cords.
For other connections (not concerning IP devices) please refer to the following table:
Segment
Type of wire
1mm
2
single cable
A – OP1
60 m
A – OP2
60 m
A – OP3
100 m
B – OP5
30 m
B – OP6
30 m
B – local power supply
25 m