![urmet domus 1060/601 Installer And User Manual Download Page 24](http://html1.mh-extra.com/html/urmet-domus/1060-601/1060-601_installer-and-user-manual_1062463024.webp)
24
DS1060-102A
In which you can add new cameras via the menu
Add New Camera
:
The cameras that may be used are of the type RTSP (Real Time Streaming Protocol), see list under section
3 ACCESSORY DEVICES
.
For correct camera operation, it is necessary to set the parameters shown in the screen above.
The button
TEST
allows you to have a preview of the camera. The button
ADD NEW CAMERA
allows you to add
a camera to the list.
The parameters that must be chosen and con
fi
gured for the correct operation of the RTSP camera are the
following:
CAMERA NAME
: general name to assign to the RTSP camera; in the list of the cameras pre-set for the auto-
on function, the RTSP camera will appear with this name (you can also assign an image identifying the camera
via the icon with the ‘’+’’ symbol to the left of the screen);
IP
or
DOMAIN
: assign to the RTSP camera the IP address present in the corresponding
fi
eld;
STREAM NAME
: in the camera page for the various streaming videos enter the corresponding URL. It is
recommended choosing video streaming with H.264 or MJPEG code and frame rate
≥
5fps;
PORT
: The default port is 554;
USER NAME / PASSWORD
: to enter if the camera requires authentication for video streaming.
11 TECHNICAL SPECIFICATIONS
11.1 CALLING STATION Ref. 1060/70
POWER VOLTAGE AND CONSUMPTION ON TERMINALS V+ V
Power voltage: .........................................................................................................................................
44-57 V
Current consumption during video call @ 48 V
: ....................................................................................
125 mA
Current consumption in standby @ 48 V
: ...............................................................................................
70 mA
Max consumption: .............................................................................................................................................
6 W
RELAY CONTACT CAPACITY (C, CN, NO) TO ACTIVATE GARAGE GATE OPENER
Maximum switching voltage: .......................................................................................................................
30 V
Maximum switching current: ............................................................................................................................
3,5 A
Maximum switching load: .....................................................................................................................
40 VA 25 W
Working temperature range: ..........................................................................................................
-10 °C ÷ +50 °C
Output for electric lock: ..............................................................................................................
12 Vac max 15 VA
Supplied
fl
ush-mounted box dimensions (L x H x D): ................................................................
118 x 204 x 45 mm
11.2 MONITOR Ref. 1060/31
POE input voltage: ..................................................................................................................................
48-54 V
External power supply voltage: ..........................................................................................................
24/48 V
(#)
Max consumption: ............................................................................................................................................
12 W
Display: ..........................................................................................................................................................
7” TFT
Touchscreen: ..........................................................................................................................................
Capacitive
•
•
•
•
•