Remember, it is necessary to connect all three outputs to an alarm central or an electronic panel that
can see all those information in real time and take proper action.
In order to avoid accidental activation with subsequent fog emission, the inputs are in “negative
security”, for this reason the disconnection of a wire does not cause activation.
So it is necessary to check carefully the reliability of connections and protect the cables to the control
panel to avoid the risk of accidental damages.
UMPER W4
: if closed, it activates external PIR.
JUMPER W3
: reserved for diagnostic, DO NOT USE!
JUMPER W2
: if closed, it activates antirobbery function (instant shot through antirobbery button).
JUMPER W1
: if closed, it activates the serial port to use additional boards, like LAN board (not relay board).
INPUTS
+ 12V Power input
The power supply is connected to those inputs.
INPUT SIGNALS
A By connecting this input to positive, FAST 01 2C PRO PLUS is armed, blue frontal LED is switched on and when
the machine reaches proper temperature it means that it is ready for shooting.
S Putting this input to positive, if FAST 01 2C PRO PLUS is hot and armed, starts fog emission for the set time
(see paragraph 11). In case of alarm, opening ARM input, the fog emission stops immediately, even if the time set wasn’t
reached.
VALIDATION INPUT
In order to validate this input, it’s necessary to insert the jumper W4 with the unit switched OFF.
This input automatically generates AND function with input S.
If any input receives the shooting command, the generator doesn’t emit fog if within 1 minute doesn’t receive the command
also from the second input.
P+
Output positive to give power to a validation sensor or a remote control receiver, max 300 mA.
P-
Output negative to give power to a validation sensor or a remote control receiver, max 300 mA.
PV
Validation input. It’s possible to connect to this input a validation sensor with a contact normally closed conncted
to the terminal P-.
The PV input can be connected to external devices such as PIR or door sensors and behaves as an additional firing validation
input. When the PV function is active, by closing the W4 jumper, the emission of fog will be possible ONLY if the SHOOT and PV
commands have both been received, in any order, in a time interval not exceeding 60 seconds. After the shooting in these
conditions both inputs will be inhibited for 2 minutes to avoid false activations.
OUTPUTS
E
This output (NPN Open Collector) closes towards negative direction when the bag is empty.This output (NPN open collector)
closes towards negative when the fogging machine emitted fog for at least 100’’ or when the bag is empty. The signal is
activated by a sensor that detects the absence of liquid just while shooting.
The empty bag signal is deactivated only making the RESET (see paragraph 14). For this reasons, if the bag is not inserted,
or there is an empty bag inside, FAST 01 2C PRO PLUS will detect it just after a shot.
F
This output (NPN Open Collector) closes towards negative when there is a malfunction (such as batteries expired, fault of
power supply or temperature control fault), which compromises the functioning of the device and which requires a technical
action. Fault signal due to supply absence has a delay of 20 minutes.
T
This output (NPN Open Collector) closes towards negative direction when you open the bag door or when the accelerometer
detects a sudden movement (such as the detachment from the wall).
C
This output (NPN open collector) closes towards negative only after that the system has emitted fog for the set time.
If the emission of fog is interrupted (if there is an interruption of ARM command, if the glycol finishes, if there is not thermal
autonomy anymore) this output will not change its status.