Remember, it is necessary to connect all three outputs to an alarm central or an electronic panel that 

can see all those information in real time and take proper action.

In order to avoid accidental activation with subsequent fog emission, the inputs are in “negative 

security”, for this reason the disconnection of a wire does not cause activation.

So it is necessary to check carefully the reliability of connections and protect the cables to the control 

panel to avoid the risk of accidental damages.

UMPER W4

: if closed, it activates external PIR. 

JUMPER W3

: reserved for diagnostic, DO NOT USE!

JUMPER W2

: if closed, it activates antirobbery function (instant shot through antirobbery button).

JUMPER W1

: if closed, it activates the serial port to use additional boards, like LAN board (not relay board).

INPUTS
+ 12V Power input

The power supply is connected to those inputs.

INPUT SIGNALS

A By connecting this input to positive, FAST 01 2C PRO PLUS is armed, blue frontal LED is switched on and when

the machine reaches proper temperature it means that it is ready for shooting.

S Putting this input to positive, if FAST 01 2C PRO PLUS is hot and armed, starts fog emission for the set time 

(see paragraph 11). In case of alarm, opening ARM input, the fog emission stops immediately, even if the time set wasn’t 

reached.

VALIDATION INPUT

In order to validate this input, it’s necessary to insert the jumper W4 with the unit switched OFF. 

This input automatically generates AND function with input S.

If any input receives the shooting command, the generator doesn’t emit fog if within 1 minute doesn’t receive the command 

also from the second input.

P+ 

Output positive to give power to a validation sensor or a remote control receiver, max 300 mA.

P-

  Output negative to give power to a validation sensor or a remote control receiver, max 300 mA.

PV

  Validation input. It’s possible to connect to this input a validation sensor with a contact normally closed conncted 

to the terminal P-.

The PV input can be connected to external devices such as PIR or door sensors and behaves as an additional firing validation 

input. When the PV function is active, by closing the W4 jumper, the emission of fog will be possible ONLY if the SHOOT and PV 

commands have both been received, in any order, in a time interval not exceeding 60 seconds. After the shooting in these 

conditions both inputs will be inhibited for 2 minutes to avoid false activations. 

OUTPUTS
E

 This output (NPN Open Collector) closes towards negative direction when the bag is empty.This output (NPN open collector) 

closes towards negative when the fogging machine emitted fog for at least 100’’ or when the bag is empty. The signal is 
activated by a sensor that detects the absence of liquid just while shooting.
The empty bag signal is deactivated only making the RESET (see paragraph 14). For this reasons, if the bag is not inserted, 
or there is an empty bag inside, FAST 01 2C PRO PLUS will detect it just after a shot.

F

 This output (NPN Open Collector) closes towards negative when there is a malfunction (such as batteries expired, fault of 

power supply or temperature control fault), which compromises the functioning of the device and which requires a technical 
action. Fault signal due to supply absence has a delay of 20 minutes.

T

 This output (NPN Open Collector) closes towards negative direction when you open the bag door or when the accelerometer 

detects a sudden movement (such as the detachment from the wall).

C

 This output (NPN open collector) closes towards negative only after that the system has emitted fog for the set time. 

If the emission of fog is interrupted (if there is an interruption of ARM command, if the glycol finishes, if there is not thermal 

autonomy anymore) this output will not change its status.

9

Summary of Contents for FAST 01 2C PRO PLUS

Page 1: ...FAST PRO PLUS FAST 01 2C PRO PLUS INSTALLATION AND USE MANUAL Installation and use manual model FAST01 2CPRO PLUS 120V 230Vrev 15 02 2022 page 1 of 23 ENGLISH MANUAL ...

Page 2: ...llations tips for fogging systems page 4 05 Technical specifications page 5 06 How to activate the system page 6 07 Mains power supply page 7 08 Power supply connections page 7 09 Description of input and output connections page 8 10 Connection examples page 10 11 Front LEDS Meaning page 14 12 Shooting time settings and fog flow direction page 14 13 Nozzle tamper page 16 14 Installation exchange a...

Page 3: ... is not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol water and alcohol Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above At the date of printing of this manual it has never been pointed out any p...

Page 4: ...me table avoid overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create a residue problems in the room 13 UR Fog continues to be effective for up to 2 hours without 230 V or 120 V main power thanks to the insulation system which maintains the temperature in the heating system 14 Install at an height of about 2 5...

Page 5: ...ax power on heating system Average power consumption during heating time Max heating time Max consumption at 12 V Power consumption at 12 V Battery type not included Door tamper Anti tear off and anti shift 22 Kg 1200 m3 1400 m3 2 x 600 ml about 2 5 hours 2 x 300 W 540 W about 2 5 hours 60 W 500 mA while shooting 60 mA in stand by Pb 2 Ah 12V Tamper screw Accelerometer Industrial standard as from ...

Page 6: ...eating CAUTION to avoid injuries please securely fix the fogging machine to the wall according to the installation instructions In case of installation behind a wall it is possible to request a nozzle extension 7 cm After removing the machine from the package unscrew the two screws that stop the right side panel and remove it Remove tamper screw and shell screws from inside At this point it is pos...

Page 7: ...he shooting temperature The heating element is rated at 600 W at the very beginning power consumption is about 500 W and in some minutes it goes down reaching average consumption of about 110 W Do not use inverter or UPS if you are not sure that they generate a true sine wave not a rebuilt one Ask please to the UPS manifacturer the correspondance of such features before proceeding with the connect...

Page 8: ... power input GND power input ARM Arming input SHOOT Shooting input GND OUTPUTS EMPTY Empty cylinder output FAULT Fault output TAMPER Tamper output CONFIRM Shot confirmation output PIR SENSOR VALIDATION INPUT P 12V for PIR power supply P GND for PIR power supply COM PIR PV N C PIR 09 DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS V J6 Serial bus RS232 12V power input INPUTS OUTPUTS Shooting seconds se...

Page 9: ...n sensor or a remote control receiver max 300 mA PV Validation input It s possible to connect to this input a validation sensor with a contact normally closed conncted to the terminal P The PV input can be connected to external devices such as PIR or door sensors and behaves as an additional firing validation input When the PV function is active by closing the W4 jumper the emission of fog will be...

Page 10: ...dard alarm system 10 CONNECTION EXAMPLES The diagrams and examples below are intended to better understand the operation of the inputs outputs None of the diagrams below represents the single scheme to perform as in respect of the reference standard EN50131 8 there are precise indications and only using all inputs and outputs on the PCB it is possible to be compliant to the standard For safety rea...

Page 11: ...ST PRO PLUS B Example of connection of FAST 01 2C PRO PLUS inputs to an alarm with relay outputs ON OFF output of this alarm central is an open relay when the system is off and it is stably closed to positive as long as the system is turn on C Example of connection of FAST 01 2C PRO PLUS inputs with outputs of an alarm with open collector outputs Compared to B diagram this alarm central has only o...

Page 12: ... where the voltage of pull up resistance is lower than the power supply one The UR Fog outputs are normally opened and connected with input zones of the alarm control panel normally opened In this diagram by putting a resistance with a value required by the alarm control panel used in UR Fog terminal with not used outputs the central will see the correct resistance After the activation of an outpu...

Page 13: ...bbery closing the Jumper W2 you will obtain the immediate emission of the fog for the seconds that you set paragraph13 even if the fogging system is not armed N B Is recommend to use this function after a careful evaluation of the risks from a security consultant With p2 p3 p4 p5 jumpers is possible to select if the contact should be normally opened or normally closed 1 2 empty contact 3 4 fault c...

Page 14: ...utton again the shooting time is not added to the one previously set but will restart from zero N B Before opening side door ensure that the control panel is set to service so that the opening of anti sabotage or tamper circuit does not cause any shooting ARM FAULT EMPTY RESERVE HEATING RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT m3 Systems FAST 01 2C PRO PLUS are able to...

Page 15: ...03 433 520 1560 449 539 1617 465 559 1677 482 578 1734 498 597 1791 514 616 1848 530 635 1386 546 655 1965 562 674 2022 578 693 2079 594 713 2139 610 732 2196 626 751 2253 642 770 2310 658 790 2370 674 809 2427 690 828 2484 722 867 2601 706 874 2622 738 886 2658 754 905 2715 770 924 2772 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 786 944 2832 803 963 2889 819 982 2946 ...

Page 16: ...he intruder to attempt the sabotage For this reason after the emission of the fog the compressor will be activated for 15 minutes The cylinders for FAST 01 2C PRO PLUS are guaranteed to work until the expiry date that is printed on the top N B When you close the door the buzzer will make a sound to confirm the tamper is closed Attention before opening the side door make sure that the alarm control...

Page 17: ...r placed on the power supply Verify the efficiency of the battery it should not be hot and bloated it is suggested to change it every two years due to the heavy and prolonged charge during the shot without mains power Entirety of the nozzle sphere Verificare che il foro sia rimasto cilindrico La durata media della sfera dell ugello dipende dal numero e dalla durata degli spari indicativamente into...

Page 18: ... that the pump is activated 3 Wait for the activation of the buzzer Max 30 4 Remove the obstruction taking away your hand quickly to avoid to be in contact with the hot emission of air The buzzer must stop If after 30 you don t hear the buzzer may be a loss inside the circuit please contact the service center If after removing the obstruction the buzzer doesn t stop it means that there is an obstr...

Page 19: ...AULT output remains closed This phase remains permanently until the machine is completely disarmed 3 When you connect again the machine blue and red leds flash alternately and no sound is emitted This phase lasts for 30 minutes then the output FAULT is reset and the generator starts to work again If during this process the generator is disconnected when you connect it again the time start again fr...

Page 20: ...eck the external power supply or the alarm unit The 3 frontal LED are flashing and the buzzer emits 1 beep for minute The buzzer emits 2 beep for minute The buzzer emits 3 beep for minute The buzzer emits 10 beep for minute When you connect the generator you don t hear the clicking relay For the duration of the test even GREEN LED are flashing the exchanger is not activated Wait for 2 minutes As s...

Page 21: ...ou press the reset button you don t hear the sound of the buzzer the frontal LEDS are flashing but the RED LEDS does not reset Disturbance interference or potential differences between devices In the case of strong interference lightning can occur a thermocouple reading error make a reset See paragraph 16 In case of unsuccessful restore can be occurred a potential difference or a fault Check on th...

Page 22: ...e down the identification number of the machines the date of the installation and sign in the dedicated spaces We recommend to throw away the batteries in the appropriate waste containers for recycling Heavy metals contained in them are recyclable UR Fog srl Via Toscana n 38 10099 San Mauro Torinese Italy Phone 011 01 33 037 Fax 011 01 33 005 support urfog com Legal office Via Giacinto Collegno 11...

Page 23: ... NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO It is mandatory to fill out this table in accordance with the law 23 ...

Page 24: ...UR Fog S r l Via Toscana 38 10099 San Mauro T se Torino Italy N B Ask for the PDF module writing to support urfog com ...

Reviews: