In case of an empty cylinder, the DL
EMPTY LED will switch on.
In case of a fault, the DL FAULT LED will
switch on.
By opening the cylinders door, besides
the DL TAMPER turning on, the relay will
switch as well.
Max power applicable on the outputs
is 100mA
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
FAST PRO PLUS
CENTRAL ALARM
+
L1
L2
L3
L4
E - Example of connection of FAST 01 2C PRO PLUS outputs with inputs of an alarm normally opened
F - Example of connection of FAST 01 2C PRO PLUS outputs with balanced inputs of an antitheft
The outputs shown in the diagram are not
always necessary, but only in cases where
the voltage of pull-up resistance is lower
than the power supply
one.
The UR Fog outputs are normally
opened and connected with input
zones of the alarm control panel
normally opened.
In this diagram, by putting a resistance with a value
required by the alarm control panel used, in UR Fog
terminal with not used outputs the central will see
the correct resistance. After the activation of an output,
a pull-down will occur causing the alarm in the
corresponding zone.
D - Example of connection of FAST 01 2C PRO PLUS outputs to drive LEDS and / or relays
DL EMPTY
DL FAULT
DL TAMPER
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
FAST PRO PLUS
+ 12 V
GND
RELÈ TAMPER
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
PUMP PRO PLUS
GND
12