11
MEANING OF FRONT LEDS
12
SHOOTING TIME SETTING AND FOG FLOW DIRECTION
BLUE LED
When
on The machine is armed and is hot, it’s ready to shoot.
When flashing
Something is wrong (See paragraph 17 DEFECTS AND POSSIBLE SOLUTIONS)
RED LED
When on
At least one cylinder is empty (See paragraph 14 INSTALLATION, EXCHANGE AND
CYLINDERS RESET)
When flashing
Something is wrong (See paragraph 17 DEFECTS AND POSSIBLE SOLUTIONS)
GREEN LED
When on
The machine is hot and ready for fog emission
When flashing
The heating process is in progress. In this step the machine is heating but is
not ready to shoot.
IF THE BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND OF THE BUZZER,
A PROBLEM IS DETECTED. SEE PARAGRAPH 16 (RESET FROM FAULT CONDITIONS)
The symbol of empty cylinder has the meaning of “RESERVE” too.
It means that since the last cylinder reset the machine consumed at least 50% of the estimated range of the cylinder.
The machine already shot for 35 seconds.
To set the shooting time, after opening the cylinders compartment door, at the top of
the PCB, facing the board you must move the jumper P3 in left position (closer to
the buttons S1/S2). Holding down the button S1 “SET”, 6 leds on the front will flash
and each flash is equivalent to one second.
If you press the button again, the shooting time is not added to the one previously
set, but will restart from zero.
N.B.
Before opening side door ensure that the control panel is set to
“service”, so that the opening of “anti-sabotage or tamper” circuit does
not cause any shooting.
ARM
FAULT
EMPTY
RESERVE
HEATING
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m
3
)
Systems FAST 01 2C PRO PLUS are able to produce fog for a maximum respectively 70 seconds per single shot.
The maximum quantity of 10,7 ml/s allows to fill an area of about 1200 m
3
.
There might be cases in which, due to specific characteristic of the location, nozzle type, levels of temperature and air
pressure, degree of the fog density and light in the target area, the shooting time can be increased. For example, above 5 m
of height the shooting time must be integrated and above 7 m , every additional meter should be considered as double.
HxLxP-------- Height x Width x Depth of the area to protect
D------------- Density of the produced fog
V------------- Temperature and air pressure
R------------- Acceptable residue in case of saturation of V parameter
I-------------- Intensity of the surface light
(HxLxP) x D x V x R x I
The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average
condition of temperature, air pressure and humidity.
N.B. To correctly dimension the machines it is needed to verify that the saturation of the area occurs
in faster time than the one supposed for the theft.
14